Availability: | |
---|---|
Quantity: | |
FS3G120-2AGL-70
Fanova
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 0.48±10% |
转速 Speed(RPM) | min-1 | 2580±5% |
功率消耗 Power consumption | W | 65±10% |
声压级 Sound Pressure Level | dB(A) | 65±5% |
最大风量 Max. Air Flow | CFM / m3/H | 181.85/309 |
最大静压 Max. Static Pressure | In.wg /Pa | 1.352/338 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP44 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FS3G120-2AGL-70 is a compact, high-efficiency single-inlet EC centrifugal fan designed for precision cooling in confined spaces. Featuring a galvanized steel impeller and brushless EC motor (BLEC72), it delivers focused airflow (309 m³/h max) at low noise (65 dB(A)). Optimized for 230VAC systems with PWM control, it excels in applications requiring corrosion resistance and directional airflow in tight installations.
Single-Inlet Precision Design
Focuses airflow for targeted cooling in dense equipment layouts, generating 338 Pa static pressure despite its compact 120mm frame.
Durable Galvanized Steel Impeller
34 corrosion-resistant blades ensure longevity in humid or chemical-exposed environments, outperforming plastic/aluminum alternatives.
Energy-Saving EC Motor
Consumes just 65W at 230VAC (184–270V range) while maintaining 2580 RPM—40% more efficient than traditional AC fans.
Silent & Smart Operation
Runs at 65 dB(A) with integrated +10VDC output for sensors, PWM speed control, and tach signal (FG: 2 pulses/revolution).
Lab Equipment: Fume extraction for microscopes, analyzers, or PCR machines.
Industrial Control Cabinets: Spot cooling for PLCs, drives, and power supplies.
Food Processing: Corrosion-resistant ventilation in washdown environments.
Medical Devices: Cooling for imaging consoles or sterilization units.
Q1: Why galvanized steel over plastic?
A: Superior corrosion resistance for humid/chemical environments—ideal for labs or food processing.
Q2: Can it replace standard axial fans?
A: Yes. Higher static pressure (338 Pa) enables better performance in restricted spaces.
Q3: How is the FG signal used?
A: Connect the white wire to monitor real-time RPM (2 pulses/revolution).
Q4: Is it compatible with 110VAC?
A: No. Requires 230VAC. Use a transformer for 110V regions.
Q5: What’s the lifespan in harsh conditions?
A: 50,000 hours (L10) at 40°C, enhanced by corrosion-resistant construction.
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 0.48±10% |
转速 Speed(RPM) | min-1 | 2580±5% |
功率消耗 Power consumption | W | 65±10% |
声压级 Sound Pressure Level | dB(A) | 65±5% |
最大风量 Max. Air Flow | CFM / m3/H | 181.85/309 |
最大静压 Max. Static Pressure | In.wg /Pa | 1.352/338 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP44 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FS3G120-2AGL-70 is a compact, high-efficiency single-inlet EC centrifugal fan designed for precision cooling in confined spaces. Featuring a galvanized steel impeller and brushless EC motor (BLEC72), it delivers focused airflow (309 m³/h max) at low noise (65 dB(A)). Optimized for 230VAC systems with PWM control, it excels in applications requiring corrosion resistance and directional airflow in tight installations.
Single-Inlet Precision Design
Focuses airflow for targeted cooling in dense equipment layouts, generating 338 Pa static pressure despite its compact 120mm frame.
Durable Galvanized Steel Impeller
34 corrosion-resistant blades ensure longevity in humid or chemical-exposed environments, outperforming plastic/aluminum alternatives.
Energy-Saving EC Motor
Consumes just 65W at 230VAC (184–270V range) while maintaining 2580 RPM—40% more efficient than traditional AC fans.
Silent & Smart Operation
Runs at 65 dB(A) with integrated +10VDC output for sensors, PWM speed control, and tach signal (FG: 2 pulses/revolution).
Lab Equipment: Fume extraction for microscopes, analyzers, or PCR machines.
Industrial Control Cabinets: Spot cooling for PLCs, drives, and power supplies.
Food Processing: Corrosion-resistant ventilation in washdown environments.
Medical Devices: Cooling for imaging consoles or sterilization units.
Q1: Why galvanized steel over plastic?
A: Superior corrosion resistance for humid/chemical environments—ideal for labs or food processing.
Q2: Can it replace standard axial fans?
A: Yes. Higher static pressure (338 Pa) enables better performance in restricted spaces.
Q3: How is the FG signal used?
A: Connect the white wire to monitor real-time RPM (2 pulses/revolution).
Q4: Is it compatible with 110VAC?
A: No. Requires 230VAC. Use a transformer for 110V regions.
Q5: What’s the lifespan in harsh conditions?
A: 50,000 hours (L10) at 40°C, enhanced by corrosion-resistant construction.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |