Availability: | |
---|---|
Quantity: | |
FS3G140-2AGL-90
Fanova
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 1.06±10% |
转速 Speed(RPM) | min-1 | 2580±5% |
功率消耗 Power consumption | W | 150±10% |
声压级 Sound Pressure Level | dB(A) | 70±5% |
最大风量 Max. Air Flow | CFM / m3/H | 141.24/543 |
最大静压 Max. Static Pressure | In.wg /Pa | 1.4/636 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP44 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
Product Overview
The FS3G140-2AGL-90 is a high-efficiency single-inlet centrifugal fan designed for precise airflow control in commercial and light industrial applications. Featuring EC motor technology with 230VAC compatibility, it delivers optimized performance in ventilation systems where space constraints, energy efficiency, and variable-speed operation are critical requirements.
Core Features
Ultra-Dense Blade Technology
Equipped with 38 galvanized steel blades on a 140mm impeller, generating enhanced static pressure (636 Pa) at lower noise levels (70 dB(A)) for efficient air movement in confined spaces.
EC Motor Efficiency
Delivers 543 m³/h airflow at just 150W power consumption with 0-10V/PWM speed control, reducing energy costs by up to 40% compared to traditional AC fans.
Compact Commercial Design
Single-inlet configuration with die-cast aluminum housing enables flexible integration into tight spaces while maintaining IP44 protection against dust and moisture.
Smart Control Integration
Features tachometer output (4 pulses/revolution) and +10VDC reference voltage for real-time monitoring and seamless integration with building management systems.
Applications
Commercial Refrigeration: Condenser cooling for display cases, walk-in coolers, and supermarket refrigeration systems
HVAC Ventilation: Energy recovery ventilators (ERVs) and compact air handling units
Professional Kitchen Equipment: Exhaust systems for commercial hoods, combi ovens, and steamers
Medical Cabinetry: Cooling for laboratory equipment, sterilization units, and diagnostic devices
Server Rack Cooling: Thermal management in data cabinets and network closets
European Market Equipment: Compliance with 230VAC/50Hz standards for EU-targeted machinery
Cleanroom Environments: Controlled airflow in pharmaceutical and electronics assembly areas
FAQ
Q1: How does single-inlet design benefit my application?
A: The single-inlet configuration concentrates airflow for higher static pressure efficiency in ducted systems, while reducing space requirements compared to dual-inlet fans.
Q2: Can I retrofit this to replace my existing 230VAC fan?
A: Yes, its 184-270VAC operating range makes it compatible with standard European mains voltage. Wiring follows identical L/N/PE configuration for easy replacement.
Q3: Why choose EC over traditional AC motors?
A: EC technology maintains high efficiency (up to 75%) across variable speeds, unlike AC fans which lose efficiency when throttled. This reduces energy costs significantly during partial-load operation.
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 1.06±10% |
转速 Speed(RPM) | min-1 | 2580±5% |
功率消耗 Power consumption | W | 150±10% |
声压级 Sound Pressure Level | dB(A) | 70±5% |
最大风量 Max. Air Flow | CFM / m3/H | 141.24/543 |
最大静压 Max. Static Pressure | In.wg /Pa | 1.4/636 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP44 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
Product Overview
The FS3G140-2AGL-90 is a high-efficiency single-inlet centrifugal fan designed for precise airflow control in commercial and light industrial applications. Featuring EC motor technology with 230VAC compatibility, it delivers optimized performance in ventilation systems where space constraints, energy efficiency, and variable-speed operation are critical requirements.
Core Features
Ultra-Dense Blade Technology
Equipped with 38 galvanized steel blades on a 140mm impeller, generating enhanced static pressure (636 Pa) at lower noise levels (70 dB(A)) for efficient air movement in confined spaces.
EC Motor Efficiency
Delivers 543 m³/h airflow at just 150W power consumption with 0-10V/PWM speed control, reducing energy costs by up to 40% compared to traditional AC fans.
Compact Commercial Design
Single-inlet configuration with die-cast aluminum housing enables flexible integration into tight spaces while maintaining IP44 protection against dust and moisture.
Smart Control Integration
Features tachometer output (4 pulses/revolution) and +10VDC reference voltage for real-time monitoring and seamless integration with building management systems.
Applications
Commercial Refrigeration: Condenser cooling for display cases, walk-in coolers, and supermarket refrigeration systems
HVAC Ventilation: Energy recovery ventilators (ERVs) and compact air handling units
Professional Kitchen Equipment: Exhaust systems for commercial hoods, combi ovens, and steamers
Medical Cabinetry: Cooling for laboratory equipment, sterilization units, and diagnostic devices
Server Rack Cooling: Thermal management in data cabinets and network closets
European Market Equipment: Compliance with 230VAC/50Hz standards for EU-targeted machinery
Cleanroom Environments: Controlled airflow in pharmaceutical and electronics assembly areas
FAQ
Q1: How does single-inlet design benefit my application?
A: The single-inlet configuration concentrates airflow for higher static pressure efficiency in ducted systems, while reducing space requirements compared to dual-inlet fans.
Q2: Can I retrofit this to replace my existing 230VAC fan?
A: Yes, its 184-270VAC operating range makes it compatible with standard European mains voltage. Wiring follows identical L/N/PE configuration for easy replacement.
Q3: Why choose EC over traditional AC motors?
A: EC technology maintains high efficiency (up to 75%) across variable speeds, unlike AC fans which lose efficiency when throttled. This reduces energy costs significantly during partial-load operation.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |