Availability: | |
---|---|
Quantity: | |
FK3G190-2APS-90
Fanova
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 1.2±10% |
转速 Speed(RPM) | min-1 | 4250±5% |
功率消耗 Power consumption | W | 170±10% |
声压级 Sound Pressure Level | dB(A) | 74±5% |
最大风量 Max. Air Flow | CFM / m3/H | 461.97/785 |
最大静压 Max. Static Pressure | In.wg /Pa | 3.56/890 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP44 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FK3G190-2APS-90 is a high-voltage EC centrifugal fan engineered for industrial ventilation systems requiring robust airflow and static pressure. Featuring an external rotor EC motor, wide AC voltage compatibility (184–270VAC), and integrated protection mechanisms, it delivers reliable cooling in demanding environments while complying with CE, RoHS, and ErP2015 standards.
High-Voltage Efficiency
Optimized for 230VAC industrial grids, it maintains stable operation across voltage fluctuations (184–270VAC) while consuming 170W at peak performance, reducing energy waste in continuous-duty applications.
Advanced Control Integration
Generates a built-in +10VDC output signal (max 1.1mA) for daisy-chaining control systems or powering sensors, alongside standard 0–10VDC/PWM speed input and FG tachometer output for real-time RPM monitoring.
High-Pressure Airflow
With a 190mm fiberglass-reinforced impeller spinning at 4,250 RPM, it achieves exceptional static pressure (890 Pa) and airflow (785 m³/h)—ideal for overcoming resistance in ducted HVAC or enclosed equipment cooling.
Ruggedized Protection
IP44-rated against dust/water ingress, paired with ball bearings and thermal cutoffs for electronics/motor (up to 115°C), ensuring 50,000-hour L10 lifespan in harsh settings (-25°C to 60°C).
Industrial HVAC: Forced-air systems, exhaust units, air handlers.
Heavy Machinery: Cooling cabinets for CNC equipment, compressors, power converters.
Energy Infrastructure: Wind turbine converters, solar inverter thermal management.
Lab Equipment: Fume extraction, environmental chamber circulation.
Q: Is this fan compatible with 110VAC power systems?
A: No—it requires 184–270VAC (50/60Hz) input. For 110V applications, consult factory for alternate models.
Q: Can the +10VDC output directly power external sensors?
A: Yes, but current draw must not exceed 1.1mA. For higher loads, use an external buffer circuit.
Q: Does it support variable frequency drives (VFDs)?
A: No—speed control is exclusively via 0–10VDC or PWM signals.
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 1.2±10% |
转速 Speed(RPM) | min-1 | 4250±5% |
功率消耗 Power consumption | W | 170±10% |
声压级 Sound Pressure Level | dB(A) | 74±5% |
最大风量 Max. Air Flow | CFM / m3/H | 461.97/785 |
最大静压 Max. Static Pressure | In.wg /Pa | 3.56/890 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP44 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FK3G190-2APS-90 is a high-voltage EC centrifugal fan engineered for industrial ventilation systems requiring robust airflow and static pressure. Featuring an external rotor EC motor, wide AC voltage compatibility (184–270VAC), and integrated protection mechanisms, it delivers reliable cooling in demanding environments while complying with CE, RoHS, and ErP2015 standards.
High-Voltage Efficiency
Optimized for 230VAC industrial grids, it maintains stable operation across voltage fluctuations (184–270VAC) while consuming 170W at peak performance, reducing energy waste in continuous-duty applications.
Advanced Control Integration
Generates a built-in +10VDC output signal (max 1.1mA) for daisy-chaining control systems or powering sensors, alongside standard 0–10VDC/PWM speed input and FG tachometer output for real-time RPM monitoring.
High-Pressure Airflow
With a 190mm fiberglass-reinforced impeller spinning at 4,250 RPM, it achieves exceptional static pressure (890 Pa) and airflow (785 m³/h)—ideal for overcoming resistance in ducted HVAC or enclosed equipment cooling.
Ruggedized Protection
IP44-rated against dust/water ingress, paired with ball bearings and thermal cutoffs for electronics/motor (up to 115°C), ensuring 50,000-hour L10 lifespan in harsh settings (-25°C to 60°C).
Industrial HVAC: Forced-air systems, exhaust units, air handlers.
Heavy Machinery: Cooling cabinets for CNC equipment, compressors, power converters.
Energy Infrastructure: Wind turbine converters, solar inverter thermal management.
Lab Equipment: Fume extraction, environmental chamber circulation.
Q: Is this fan compatible with 110VAC power systems?
A: No—it requires 184–270VAC (50/60Hz) input. For 110V applications, consult factory for alternate models.
Q: Can the +10VDC output directly power external sensors?
A: Yes, but current draw must not exceed 1.1mA. For higher loads, use an external buffer circuit.
Q: Does it support variable frequency drives (VFDs)?
A: No—speed control is exclusively via 0–10VDC or PWM signals.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |