Availability: | |
---|---|
Quantity: | |
FS3G200-2AGL-90
Fanova
Phase | ~ | 1~ |
Nominal Voltage | VAC | 230 |
Nominal voltage range | VAC | 184~270 |
Frequency | Hz | 50/60 |
Current draw | A | 1.5±10% |
Speed(RPM) | min-1 | 1600±5% |
Power consumption | W | 220±10% |
Sound Pressure Level | dB(A) | 74±5% |
Max. Air Flow | CFM / m3/H | 588.5/1000 |
Max. Static Pressure | In.wg /Pa | 3.92/980 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
The FS3G200-2AGL-90 is a forward-curve centrifugal fan engineered for high-static-pressure applications in compact spaces. Featuring an innovative 38-blade galvanized steel impeller and EC motor (BLEC92), it delivers exceptional airflow efficiency with reduced noise. Ideal for precision ventilation systems, it combines robust performance with smart control integration.
High-Pressure Precision
Generates 980 Pa (3.92 In.wg) static pressure—ideal for ducted systems—using a dense 38-blade galvanized steel impeller. Moves 1000 m³/h (589 CFM) at just 74 dB(A), balancing power and quiet operation.
Forward-Curve Efficiency
Unique blade design maximizes airflow in confined spaces (200mm footprint), outperforming standard backward-curve fans in low-RPM/high-pressure scenarios.
Self-Powered Control Hub
Integrated +10VDC output (red wire) powers external sensors/controllers. Supports 0–10V/PWM speed tuning (yellow wire) and tach feedback (4 pulses/revolution via FG signal).
Industrial Resilience
Galvanized steel construction resists corrosion in humid environments. IP44-rated for dust/moisture protection, operating in -25°C to 60°C with 50,000-hour L10 lifespan.
HVAC Air Handlers: High-pressure airflow in compact commercial units.
Cleanrooms & Labs: Filtered ventilation for contamination-sensitive environments.
Medical Equipment Cooling: Precision thermal management in imaging devices.
Food Processing: Corrosion-resistant ventilation for humid/washdown areas.
Q: Why 38 blades?
A: Maximizes air displacement per rotation, enabling high pressure at lower RPM (1600) for quieter operation vs. conventional designs.
Q: Can the +10VDC output drive multiple sensors?
A: Yes—but limit to ≤1.1mA total draw. Chain devices using the GND (blue) wire.
Q: How to reduce noise further?
A: Use PWM control to lower RPM. Noise drops ~12 dB(A) at 50% speed.
Q: Is galvanized steel better than plastic?
A: Superior in high-moisture/corrosive environments (e.g., food processing, marine).
Phase | ~ | 1~ |
Nominal Voltage | VAC | 230 |
Nominal voltage range | VAC | 184~270 |
Frequency | Hz | 50/60 |
Current draw | A | 1.5±10% |
Speed(RPM) | min-1 | 1600±5% |
Power consumption | W | 220±10% |
Sound Pressure Level | dB(A) | 74±5% |
Max. Air Flow | CFM / m3/H | 588.5/1000 |
Max. Static Pressure | In.wg /Pa | 3.92/980 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
The FS3G200-2AGL-90 is a forward-curve centrifugal fan engineered for high-static-pressure applications in compact spaces. Featuring an innovative 38-blade galvanized steel impeller and EC motor (BLEC92), it delivers exceptional airflow efficiency with reduced noise. Ideal for precision ventilation systems, it combines robust performance with smart control integration.
High-Pressure Precision
Generates 980 Pa (3.92 In.wg) static pressure—ideal for ducted systems—using a dense 38-blade galvanized steel impeller. Moves 1000 m³/h (589 CFM) at just 74 dB(A), balancing power and quiet operation.
Forward-Curve Efficiency
Unique blade design maximizes airflow in confined spaces (200mm footprint), outperforming standard backward-curve fans in low-RPM/high-pressure scenarios.
Self-Powered Control Hub
Integrated +10VDC output (red wire) powers external sensors/controllers. Supports 0–10V/PWM speed tuning (yellow wire) and tach feedback (4 pulses/revolution via FG signal).
Industrial Resilience
Galvanized steel construction resists corrosion in humid environments. IP44-rated for dust/moisture protection, operating in -25°C to 60°C with 50,000-hour L10 lifespan.
HVAC Air Handlers: High-pressure airflow in compact commercial units.
Cleanrooms & Labs: Filtered ventilation for contamination-sensitive environments.
Medical Equipment Cooling: Precision thermal management in imaging devices.
Food Processing: Corrosion-resistant ventilation for humid/washdown areas.
Q: Why 38 blades?
A: Maximizes air displacement per rotation, enabling high pressure at lower RPM (1600) for quieter operation vs. conventional designs.
Q: Can the +10VDC output drive multiple sensors?
A: Yes—but limit to ≤1.1mA total draw. Chain devices using the GND (blue) wire.
Q: How to reduce noise further?
A: Use PWM control to lower RPM. Noise drops ~12 dB(A) at 50% speed.
Q: Is galvanized steel better than plastic?
A: Superior in high-moisture/corrosive environments (e.g., food processing, marine).
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |