FB3G250-2AAY-30
Fanova
Phase | ~ | 1~ |
Nominal Voltage | VAC | 230 |
Nominal voltage range | VAC | 184~270 |
Frequency | Hz | 50/60 |
Current draw | A | 3.3±10% |
Speed(RPM) | min-1 | 3000±5% |
Power consumption | W | 750±10% |
Sound Pressure Level | dB(A) | 87±5% |
Max. Air Flow | CFM / m3/H | 2018.56/3430 |
Max. Static Pressure | In.wg /Pa | 4.31/1077 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
The FB3G250-2AAY-30 is a high-capacity centrifugal fan designed for industrial-scale ventilation. Featuring a powerful BLEC137 EC motor and 8-blade aluminum impeller, it delivers exceptional 3,430 m³/h (2,019 CFM) airflow at 1,077 Pa static pressure. Operating at 230VAC with Class F insulation, it provides robust performance for demanding applications requiring high airflow volumes and pressure capabilities.
1. Industrial Airflow Capacity
8-blade aluminum impeller generates massive 3,430 m³/h airflow - ideal for large-space ventilation. High-pressure capability (1,077 Pa) overcomes significant system resistance.
2. Premium Motor Technology
BLEC137 EC motor operates at 3,000 RPM with Class F insulation for superior thermal resilience. Delivers 750W output while maintaining energy efficiency versus traditional AC motors.
3. Advanced Control System
Integrated RS485/MODBUS communication enables building automation integration. Includes 0-10VDC/PWM speed control + tachometer output (5 pulses/rev) for precision monitoring.
4. Heavy-Duty Protection
IP54-rated construction withstands dust/moisture ingress. Features alarm contacts (NC/COM) for immediate fault notification and 1800VAC dielectric protection.
Large industrial ventilation systems
Factory air makeup units
High-capacity HVAC central units
Process drying/cooling operations
Concert hall/arena air circulation
Q: What does Class F insulation provide?
A: 25% higher temperature tolerance than Class B - ideal for sustained heavy loads.
Q: Noise level at maximum output?
A: 87 dB(A) - recommend vibration isolation mounts for noise-sensitive installations.
Q: MODBUS implementation details?
A: Standard MODBUS-RTU protocol via RSA/RSB terminals (contact support for custom mapping).
Q: Alarm contact triggering conditions?
A: NC/COM closes during overheat, lock-rotor, or voltage fault events.
Phase | ~ | 1~ |
Nominal Voltage | VAC | 230 |
Nominal voltage range | VAC | 184~270 |
Frequency | Hz | 50/60 |
Current draw | A | 3.3±10% |
Speed(RPM) | min-1 | 3000±5% |
Power consumption | W | 750±10% |
Sound Pressure Level | dB(A) | 87±5% |
Max. Air Flow | CFM / m3/H | 2018.56/3430 |
Max. Static Pressure | In.wg /Pa | 4.31/1077 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
The FB3G250-2AAY-30 is a high-capacity centrifugal fan designed for industrial-scale ventilation. Featuring a powerful BLEC137 EC motor and 8-blade aluminum impeller, it delivers exceptional 3,430 m³/h (2,019 CFM) airflow at 1,077 Pa static pressure. Operating at 230VAC with Class F insulation, it provides robust performance for demanding applications requiring high airflow volumes and pressure capabilities.
1. Industrial Airflow Capacity
8-blade aluminum impeller generates massive 3,430 m³/h airflow - ideal for large-space ventilation. High-pressure capability (1,077 Pa) overcomes significant system resistance.
2. Premium Motor Technology
BLEC137 EC motor operates at 3,000 RPM with Class F insulation for superior thermal resilience. Delivers 750W output while maintaining energy efficiency versus traditional AC motors.
3. Advanced Control System
Integrated RS485/MODBUS communication enables building automation integration. Includes 0-10VDC/PWM speed control + tachometer output (5 pulses/rev) for precision monitoring.
4. Heavy-Duty Protection
IP54-rated construction withstands dust/moisture ingress. Features alarm contacts (NC/COM) for immediate fault notification and 1800VAC dielectric protection.
Large industrial ventilation systems
Factory air makeup units
High-capacity HVAC central units
Process drying/cooling operations
Concert hall/arena air circulation
Q: What does Class F insulation provide?
A: 25% higher temperature tolerance than Class B - ideal for sustained heavy loads.
Q: Noise level at maximum output?
A: 87 dB(A) - recommend vibration isolation mounts for noise-sensitive installations.
Q: MODBUS implementation details?
A: Standard MODBUS-RTU protocol via RSA/RSB terminals (contact support for custom mapping).
Q: Alarm contact triggering conditions?
A: NC/COM closes during overheat, lock-rotor, or voltage fault events.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |