Availability: | |
---|---|
Quantity: | |
FK3G280-2APL-90
Fanova
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 1.45±10% |
转速 Speed(RPM) | min-1 | 1950±5% |
功率消耗 Power consumption | W | 195±10% |
声压级 Sound Pressure Level | dB(A) | 71.5±5% |
最大风量 Max. Air Flow | CFM / m3/H | 1481.25/2517 |
最大静压 Max. Static Pressure | In.wg /Pa | 1.8/452 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP44 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FK3G280-2APL-90 is an industrial centrifugal fan with an integrated mounting bracket, designed for simplified installation in high-airflow ventilation systems. Powered by a brushless EC motor (BLEC92) and featuring a 280mm glass-fiber-reinforced impeller, it delivers robust airflow (2,517 m³/h) at 230VAC with optimized energy efficiency. Its bracket-enabled design, IP44 protection, and wide voltage range (184–270VAC 50/60Hz) make it ideal for rapid deployment in commercial and industrial settings.
Integrated Mounting Bracket
Pre-installed support bracket enables tool-free installation and secure positioning in ducts, enclosures, or equipment frames—reducing assembly time by up to 70% compared to bracketless models.
High-Capacity Airflow with Low Noise
Moves 2,517 m³/h air at just 71.5 dB(A)—balancing ventilation power with operational quietness for environments like workshops or agricultural facilities.
Corrosion-Resistant & Lightweight
Glass-fiber-reinforced plastic impeller resists moisture and chemicals while reducing inertial load. Paired with die-cast aluminum housing, it ensures 50,000-hour lifespan in humid/dusty conditions.
Industrial Ventilation: Factory floors, welding stations, paint booths.
Commercial HVAC: Shopping malls, warehouse air circulation.
Agricultural Systems: Livestock barns, greenhouse climate control.
Power Unit Cooling: Generator enclosures, transformer cabinets.
Q: Can the bracket angle be adjusted?
A: Fixed 90° bracket; custom angles available upon request (contact support).
Q: Is the plastic impeller durable in high-heat environments?
A: Operating temp caps at 60°C. For higher temps (e.g., ovens), use metal-impeller variants.
Q: Does it require grounding via the green/yellow wire?
A: Mandatory for safety/EMC compliance—connect to facility earth.
Q: How does it handle voltage fluctuations?
A: Tolerates 184–270VAC without performance drop; built-in over/undervoltage protection.
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 1.45±10% |
转速 Speed(RPM) | min-1 | 1950±5% |
功率消耗 Power consumption | W | 195±10% |
声压级 Sound Pressure Level | dB(A) | 71.5±5% |
最大风量 Max. Air Flow | CFM / m3/H | 1481.25/2517 |
最大静压 Max. Static Pressure | In.wg /Pa | 1.8/452 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP44 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FK3G280-2APL-90 is an industrial centrifugal fan with an integrated mounting bracket, designed for simplified installation in high-airflow ventilation systems. Powered by a brushless EC motor (BLEC92) and featuring a 280mm glass-fiber-reinforced impeller, it delivers robust airflow (2,517 m³/h) at 230VAC with optimized energy efficiency. Its bracket-enabled design, IP44 protection, and wide voltage range (184–270VAC 50/60Hz) make it ideal for rapid deployment in commercial and industrial settings.
Integrated Mounting Bracket
Pre-installed support bracket enables tool-free installation and secure positioning in ducts, enclosures, or equipment frames—reducing assembly time by up to 70% compared to bracketless models.
High-Capacity Airflow with Low Noise
Moves 2,517 m³/h air at just 71.5 dB(A)—balancing ventilation power with operational quietness for environments like workshops or agricultural facilities.
Corrosion-Resistant & Lightweight
Glass-fiber-reinforced plastic impeller resists moisture and chemicals while reducing inertial load. Paired with die-cast aluminum housing, it ensures 50,000-hour lifespan in humid/dusty conditions.
Industrial Ventilation: Factory floors, welding stations, paint booths.
Commercial HVAC: Shopping malls, warehouse air circulation.
Agricultural Systems: Livestock barns, greenhouse climate control.
Power Unit Cooling: Generator enclosures, transformer cabinets.
Q: Can the bracket angle be adjusted?
A: Fixed 90° bracket; custom angles available upon request (contact support).
Q: Is the plastic impeller durable in high-heat environments?
A: Operating temp caps at 60°C. For higher temps (e.g., ovens), use metal-impeller variants.
Q: Does it require grounding via the green/yellow wire?
A: Mandatory for safety/EMC compliance—connect to facility earth.
Q: How does it handle voltage fluctuations?
A: Tolerates 184–270VAC without performance drop; built-in over/undervoltage protection.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |