Availability: | |
---|---|
Quantity: | |
FB3G280-2APL-20
Fanova
Phase | ~ | 1~ |
Nominal Voltage | VAC | 230 |
Nominal voltage range | VAC | 184~270 |
Frequency | Hz | 50/60 |
Current draw | A | 2.2±10% |
Speed(RPM) | min-1 | 2750±5% |
Power consumption | W | 500±10% |
Sound Pressure Level | dB(A) | 80.7±5% |
Max. Air Flow | CFM / m3/H | 2143.32/3642 |
Max. Static Pressure | In.wg /Pa | 3.56/891 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP54 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
The FB3G280-2APL-20 is a space-optimized EC centrifugal fan for medium-duty industrial airflow systems. Driven by a 230VAC motor (BLEC102), its 280mm composite impeller delivers 3642 m³/h airflow and 891 Pa static pressure at just 500W power. With IP54 protection, Class B insulation, and integrated Modbus communication, it operates continuously (S1) in -25°C to 60°C environments.
Lightweight High-Pressure Design
A 6-blade PP+GF impeller reduces mass by 30% vs. metal alternatives while maintaining 891 Pa pressure for ducted systems up to 15m.
Real-Time Fault Monitoring
Dedicated alarm contacts (Orange/COM-Gray) trigger upon lock-rotor or overheating—connect to PLC for instant system alerts.
Optimized Acoustic Profile
Generates only 80.7 dB(A) at full load—20% quieter than comparable metal impellers—due to aerodynamic blade geometry.
Energy-Smart Operation
Draws 2.2A at 230VAC with soft-start control, minimizing inrush current in battery/UPS-backed installations.
Industrial Process Cooling: Laser cutters, CNC machines requiring 800+ Pa static pressure.
Compact HVAC Units: Rooftop units and air handlers where weight reduction is critical.
Modular Ventilation Systems: Plug-and-play integration with BMS via RS485 Modbus (RSA/RSB).
Q1: How to use the alarm contacts?
A: Wire Orange (NC) and Gray (COM) to a PLC input. Contacts close during faults (e.g., temperature >85°C or motor lock).
Q2: Is plastic impeller suitable for 891 Pa pressure?
A: Yes. Glass-fiber reinforcement ensures stability at 2750 RPM. Avoid abrasive particle ingress.
Q3: Can RPM be controlled via Modbus?
A: Yes. Use RSA (Green) and RSB (Purple) for MODBUS-RTU speed commands—default protocol, others configurable.
Q4: Why choose this over the FB3G310 model?
A: 15% smaller footprint, 38% lower power, and equivalent pressure—ideal where space/power are constrained.
Phase | ~ | 1~ |
Nominal Voltage | VAC | 230 |
Nominal voltage range | VAC | 184~270 |
Frequency | Hz | 50/60 |
Current draw | A | 2.2±10% |
Speed(RPM) | min-1 | 2750±5% |
Power consumption | W | 500±10% |
Sound Pressure Level | dB(A) | 80.7±5% |
Max. Air Flow | CFM / m3/H | 2143.32/3642 |
Max. Static Pressure | In.wg /Pa | 3.56/891 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP54 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
The FB3G280-2APL-20 is a space-optimized EC centrifugal fan for medium-duty industrial airflow systems. Driven by a 230VAC motor (BLEC102), its 280mm composite impeller delivers 3642 m³/h airflow and 891 Pa static pressure at just 500W power. With IP54 protection, Class B insulation, and integrated Modbus communication, it operates continuously (S1) in -25°C to 60°C environments.
Lightweight High-Pressure Design
A 6-blade PP+GF impeller reduces mass by 30% vs. metal alternatives while maintaining 891 Pa pressure for ducted systems up to 15m.
Real-Time Fault Monitoring
Dedicated alarm contacts (Orange/COM-Gray) trigger upon lock-rotor or overheating—connect to PLC for instant system alerts.
Optimized Acoustic Profile
Generates only 80.7 dB(A) at full load—20% quieter than comparable metal impellers—due to aerodynamic blade geometry.
Energy-Smart Operation
Draws 2.2A at 230VAC with soft-start control, minimizing inrush current in battery/UPS-backed installations.
Industrial Process Cooling: Laser cutters, CNC machines requiring 800+ Pa static pressure.
Compact HVAC Units: Rooftop units and air handlers where weight reduction is critical.
Modular Ventilation Systems: Plug-and-play integration with BMS via RS485 Modbus (RSA/RSB).
Q1: How to use the alarm contacts?
A: Wire Orange (NC) and Gray (COM) to a PLC input. Contacts close during faults (e.g., temperature >85°C or motor lock).
Q2: Is plastic impeller suitable for 891 Pa pressure?
A: Yes. Glass-fiber reinforcement ensures stability at 2750 RPM. Avoid abrasive particle ingress.
Q3: Can RPM be controlled via Modbus?
A: Yes. Use RSA (Green) and RSB (Purple) for MODBUS-RTU speed commands—default protocol, others configurable.
Q4: Why choose this over the FB3G310 model?
A: 15% smaller footprint, 38% lower power, and equivalent pressure—ideal where space/power are constrained.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |