Availability: | |
---|---|
Quantity: | |
FG3G350-2APN-90不带网罩
Fanova
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 1.15±10% |
转速 Speed(RPM) | min-1 | 1580±5% |
功率消耗 Power consumption | W | 160±10% |
声压级 Sound Pressure Level | dB(A) | 63±5% |
最大风量 Max. Air Flow | CFM / m3/H | 2059.75/3500 |
最大静压 Max. Static Pressure | In.wg /Pa | 0.54/135 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP44 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FK3G220-85PY-90 is an industrial-grade backward-curved centrifugal fan engineered by Fanova for high-pressure ventilation. Combining a brushless DC motor (BLDC92) with a fiberglass-reinforced plastic impeller, it delivers robust airflow against resistance while supporting intelligent speed control. Built to endure harsh environments (IP44 rated, -25°C to 60°C), it excels in systems demanding reliability and adaptability.
Pressure-Optimized Airflow
Generates 820 Pa static pressure – ideal for pushing air through dense filters, duct networks, or compact heat exchangers without performance drop-off.
Smart Motor Management
Embedded protections (soft-start, voltage lockout, thermal cutoffs) + dual-control input (0-10V/PWM) with real-time RPM feedback (FG signal) for seamless system integration.
Industrial Toughness
Reinforced impeller resists deformation at high speeds; ball bearings and die-cast aluminum housing ensure 50,000-hour lifespan in dusty/humid conditions.
Drop-in Safety Compliance
Pre-certified for CE, RoHS, ISO 9001, and EU ErP – reduces validation time for HVAC/industrial equipment manufacturers.
Critical Cooling: Server racks, laser cutters, power cabinets.
Air Handling Units (AHUs): Forced draft in commercial HVAC.
Filtration Systems: High-static-pressure exhaust for dust collectors.
Medical Devices: Ventilation requiring low-noise operation.
Q: Can it run continuously at full load?
A: Yes – rated for S1 continuous duty at 60°C ambient.
Q: Is reverse rotation possible?
A: No – impeller design is unidirectional (clockwise, viewed toward rotor).
Q: How to prevent wiring damage?
A: Never lift by cables; use mounting brackets. Custom cable lengths available.
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 1.15±10% |
转速 Speed(RPM) | min-1 | 1580±5% |
功率消耗 Power consumption | W | 160±10% |
声压级 Sound Pressure Level | dB(A) | 63±5% |
最大风量 Max. Air Flow | CFM / m3/H | 2059.75/3500 |
最大静压 Max. Static Pressure | In.wg /Pa | 0.54/135 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP44 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FK3G220-85PY-90 is an industrial-grade backward-curved centrifugal fan engineered by Fanova for high-pressure ventilation. Combining a brushless DC motor (BLDC92) with a fiberglass-reinforced plastic impeller, it delivers robust airflow against resistance while supporting intelligent speed control. Built to endure harsh environments (IP44 rated, -25°C to 60°C), it excels in systems demanding reliability and adaptability.
Pressure-Optimized Airflow
Generates 820 Pa static pressure – ideal for pushing air through dense filters, duct networks, or compact heat exchangers without performance drop-off.
Smart Motor Management
Embedded protections (soft-start, voltage lockout, thermal cutoffs) + dual-control input (0-10V/PWM) with real-time RPM feedback (FG signal) for seamless system integration.
Industrial Toughness
Reinforced impeller resists deformation at high speeds; ball bearings and die-cast aluminum housing ensure 50,000-hour lifespan in dusty/humid conditions.
Drop-in Safety Compliance
Pre-certified for CE, RoHS, ISO 9001, and EU ErP – reduces validation time for HVAC/industrial equipment manufacturers.
Critical Cooling: Server racks, laser cutters, power cabinets.
Air Handling Units (AHUs): Forced draft in commercial HVAC.
Filtration Systems: High-static-pressure exhaust for dust collectors.
Medical Devices: Ventilation requiring low-noise operation.
Q: Can it run continuously at full load?
A: Yes – rated for S1 continuous duty at 60°C ambient.
Q: Is reverse rotation possible?
A: No – impeller design is unidirectional (clockwise, viewed toward rotor).
Q: How to prevent wiring damage?
A: Never lift by cables; use mounting brackets. Custom cable lengths available.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |