Availability: | |
---|---|
Quantity: | |
FG3G400-2APL-20带网罩
Fanova
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 2.18±10% |
转速 Speed(RPM) | min-1 | 1760±5% |
功率消耗 Power consumption | W | 500±10% |
声压级 Sound Pressure Level | dB(A) | 79±5% |
最大风量 Max. Air Flow | CFM / m3/H | 3472.15/5900 |
最大静压 Max. Static Pressure | In.wg /Pa | 0.96/240 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP54 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FG3G400-2APL-20 is a safety-grille equipped axial EC fan designed for environments requiring personnel protection without compromising airflow. Featuring a robust wire mesh guard and BLEC102 EC motor, it delivers 5,900 m³/h (3,472 CFM) airflow at 240 Pa (0.96 in.wg) static pressure. Ideal for accessible installations, its IP54-rated housing and 230VAC operation ensure reliable performance in workshops, public spaces, and industrial settings where accidental contact is a concern.
Integrated Safety Grille
Heavy-duty wire mesh prevents finger/hand access to the 400mm rotating impeller, meeting ISO 13857 safety standards for public and industrial spaces.
High-Flow Low-Noise Design
Moves substantial air volumes at 79 dB(A)—quieter than most industrial fans—thanks to precision-balanced glass-fiber blades and EC motor efficiency (500W consumption).
Drop-in Replacement Ready
Matches standard AC fan dimensions while offering 30% energy savings via EC technology. Pre-wired for 0–10V/PWM/RS485 control compatibility.
Factory Floor Ventilation: Worker-safe airflow in assembly lines or packing areas.
Educational/Healthcare Facilities: Corridor or lab ventilation where safety is paramount.
Commercial Kitchen Exhausts: Grease-resistant airflow with personnel protection.
Outdoor Equipment Enclosures: Weather-protected cooling for ATMs or EV chargers.
Q1: Can the grille withstand impact?
A1: Yes. 3mm steel wire mesh resists 50J impacts (tested per IEC 60068-2-75).
Q2: Does the grille reduce performance?
A2: Minimal effect—airflow loss <5% vs. open-frame models. The aerodynamic design mitigates turbulence.
Q3: How often should grilles be inspected?
A3: Visually check monthly for dents/debris; clean quarterly with mild detergent.
Q4: Is the grille removable for maintenance?
A4: Yes—secured with tamper-resistant bolts. Always power off before removal.
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 2.18±10% |
转速 Speed(RPM) | min-1 | 1760±5% |
功率消耗 Power consumption | W | 500±10% |
声压级 Sound Pressure Level | dB(A) | 79±5% |
最大风量 Max. Air Flow | CFM / m3/H | 3472.15/5900 |
最大静压 Max. Static Pressure | In.wg /Pa | 0.96/240 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP54 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FG3G400-2APL-20 is a safety-grille equipped axial EC fan designed for environments requiring personnel protection without compromising airflow. Featuring a robust wire mesh guard and BLEC102 EC motor, it delivers 5,900 m³/h (3,472 CFM) airflow at 240 Pa (0.96 in.wg) static pressure. Ideal for accessible installations, its IP54-rated housing and 230VAC operation ensure reliable performance in workshops, public spaces, and industrial settings where accidental contact is a concern.
Integrated Safety Grille
Heavy-duty wire mesh prevents finger/hand access to the 400mm rotating impeller, meeting ISO 13857 safety standards for public and industrial spaces.
High-Flow Low-Noise Design
Moves substantial air volumes at 79 dB(A)—quieter than most industrial fans—thanks to precision-balanced glass-fiber blades and EC motor efficiency (500W consumption).
Drop-in Replacement Ready
Matches standard AC fan dimensions while offering 30% energy savings via EC technology. Pre-wired for 0–10V/PWM/RS485 control compatibility.
Factory Floor Ventilation: Worker-safe airflow in assembly lines or packing areas.
Educational/Healthcare Facilities: Corridor or lab ventilation where safety is paramount.
Commercial Kitchen Exhausts: Grease-resistant airflow with personnel protection.
Outdoor Equipment Enclosures: Weather-protected cooling for ATMs or EV chargers.
Q1: Can the grille withstand impact?
A1: Yes. 3mm steel wire mesh resists 50J impacts (tested per IEC 60068-2-75).
Q2: Does the grille reduce performance?
A2: Minimal effect—airflow loss <5% vs. open-frame models. The aerodynamic design mitigates turbulence.
Q3: How often should grilles be inspected?
A3: Visually check monthly for dents/debris; clean quarterly with mild detergent.
Q4: Is the grille removable for maintenance?
A4: Yes—secured with tamper-resistant bolts. Always power off before removal.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |