FS3G180-2AGL-20
Fanova
Phase | ~ | 1~ |
Nominal Voltage | VAC | 230 |
Nominal voltage range | VAC | 184~270 |
Frequency | Hz | 50/60 |
Current draw | A | 2.2±10% |
Speed(RPM) | min-1 | 2480±5% |
Power consumption | W | 495±10% |
Sound Pressure Level | dB(A) | 76±5% |
Max. Air Flow | CFM / m3/H | 717.97/1220 |
Max. Static Pressure | In.wg /Pa | 5.26/1315 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP54 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
The FS3G180-2AGL-20 is a high-pressure centrifugal fan engineered for demanding industrial applications requiring extreme static pressure (1315 Pa) and robust airflow control. Featuring a galvanized steel impeller with 38 blades and a brushless EC motor (BLEC102), it delivers focused ventilation in compact spaces while operating at 230VAC. With IP54 protection and integrated alarm contacts, it ensures reliability in harsh environments.
Ultra-High Static Pressure Performance
Generates 1315 Pa (5.26 in.wg)—ideal for overcoming dense resistance in ducted systems, filtration units, or industrial exhausts. The 180mm impeller optimizes pressure efficiency without compromising airflow (1220 m³/h).
Industrial-Grade Durability
Constructed with galvanized steel blades and ball bearings for corrosion resistance and extended lifespan (50,000 hours L10). IP54 rating protects against dust/moisture ingress in demanding settings like manufacturing plants.
Advanced Control & Monitoring
Supports dual-speed control (0–10VDC/PWM) and RS485 Modbus communication (via RSA/RSB wires). Includes FG tachometer (5 pulses/rev) for RPM feedback and dry-contact alarms (NC/COM) for fault detection.
Industrial Dust Collection: High-pressure extraction in woodworking, metal processing, or chemical facilities.
HVAC Pressure Boosting: Supplemental airflow in long-duct commercial systems or cleanrooms.
Process Cooling: Targeted heat dissipation in heavy machinery or power electronics enclosures.
Q1: How do the alarm contacts (NC/COM) function?
They trigger when faults occur (e.g., overheating or blockage), sending signals to control systems for immediate intervention—no external power required.
Q2: Can I daisy-chain multiple fans via Modbus?
Yes—use the RSA (Green) and RSB (Purple) wires for RS485 networks, enabling centralized control and diagnostics across installations.
Q3: Is this fan suitable for corrosive environments?
The galvanized steel impeller resists corrosion, but for highly acidic/alkaline settings, consult support for optional coatings.
Phase | ~ | 1~ |
Nominal Voltage | VAC | 230 |
Nominal voltage range | VAC | 184~270 |
Frequency | Hz | 50/60 |
Current draw | A | 2.2±10% |
Speed(RPM) | min-1 | 2480±5% |
Power consumption | W | 495±10% |
Sound Pressure Level | dB(A) | 76±5% |
Max. Air Flow | CFM / m3/H | 717.97/1220 |
Max. Static Pressure | In.wg /Pa | 5.26/1315 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP54 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
The FS3G180-2AGL-20 is a high-pressure centrifugal fan engineered for demanding industrial applications requiring extreme static pressure (1315 Pa) and robust airflow control. Featuring a galvanized steel impeller with 38 blades and a brushless EC motor (BLEC102), it delivers focused ventilation in compact spaces while operating at 230VAC. With IP54 protection and integrated alarm contacts, it ensures reliability in harsh environments.
Ultra-High Static Pressure Performance
Generates 1315 Pa (5.26 in.wg)—ideal for overcoming dense resistance in ducted systems, filtration units, or industrial exhausts. The 180mm impeller optimizes pressure efficiency without compromising airflow (1220 m³/h).
Industrial-Grade Durability
Constructed with galvanized steel blades and ball bearings for corrosion resistance and extended lifespan (50,000 hours L10). IP54 rating protects against dust/moisture ingress in demanding settings like manufacturing plants.
Advanced Control & Monitoring
Supports dual-speed control (0–10VDC/PWM) and RS485 Modbus communication (via RSA/RSB wires). Includes FG tachometer (5 pulses/rev) for RPM feedback and dry-contact alarms (NC/COM) for fault detection.
Industrial Dust Collection: High-pressure extraction in woodworking, metal processing, or chemical facilities.
HVAC Pressure Boosting: Supplemental airflow in long-duct commercial systems or cleanrooms.
Process Cooling: Targeted heat dissipation in heavy machinery or power electronics enclosures.
Q1: How do the alarm contacts (NC/COM) function?
They trigger when faults occur (e.g., overheating or blockage), sending signals to control systems for immediate intervention—no external power required.
Q2: Can I daisy-chain multiple fans via Modbus?
Yes—use the RSA (Green) and RSB (Purple) wires for RS485 networks, enabling centralized control and diagnostics across installations.
Q3: Is this fan suitable for corrosive environments?
The galvanized steel impeller resists corrosion, but for highly acidic/alkaline settings, consult support for optional coatings.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |