Availability: | |
---|---|
Quantity: | |
FF3G200-2AGL-20
Fanova
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 2.5±10% |
转速 Speed(RPM) | min-1 | 1900±5% |
功率消耗 Power consumption | W | 500±10% |
声压级 Sound Pressure Level | dB(A) | 76±5% |
最大风量 Max. Air Flow | CFM / m3/H | 971.025/1650 |
最大静压 Max. Static Pressure | In.wg /Pa | 2.8/700 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP54 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FF3G200-2AGL-20 is a high-performance EC centrifugal fan engineered for industrial ventilation and airflow management. Built with an external rotor brushless motor (BLEC102), it combines energy efficiency with precise speed control. Its forward-curved design generates robust airflow (up to 1650 m³/h) and static pressure (up to 700 Pa), ideal for confined or demanding systems. Featuring an IP54-rated housing, galvanized steel impeller, and wide operating temperature range, it delivers reliability in harsh environments.
Intelligent Motor & Wide Voltage Support
Operates stably across 184–270VAC input fluctuations. The integrated EC controller enables soft-start, prevents damage from voltage spikes/drops, motor overloads, or stalls, and includes reverse-polarity protection.
Industrial-Grade Control & Monitoring
Supports 0–10VDC or PWM speed control for seamless system integration. Provides real-time RPM feedback via tachometer (FG) output (5 pulses/revolution) and includes RS485 terminals (RSA/RSB) for optional MODBUS protocol upgrades.
Ruggedized Construction for Continuous Duty
Designed for 24/7 operation (S1 duty) with a galvanized steel impeller (200mm), die-cast aluminum housing, and ball bearings. Withstands temperatures from -25°C to +60°C and features IP54 dust/water resistance.
Industrial HVAC: Ventilation, exhaust, and air handling in factories, warehouses, and production floors.
Process Cooling: Thermal management for machinery, electrical cabinets, or industrial ovens.
Air Movement Systems: Fume extraction, drying tunnels, or energy recovery units requiring high static pressure.
Q1: Can the fan be installed vertically or upside-down?
Yes, it supports installation in any orientation.
Q2: What is the default control method?
Standard control uses 0–10VDC analog or PWM signals. RS485 MODBUS requires protocol activation (contact Fanova support).
Q3: How do I monitor fan speed?
Use the FG (tachometer) output wire (white), which emits 5 pulses per revolution.
Q4: What safety protections are included?
Protections cover over/under-voltage, motor overheating, locked rotors, reverse polarity, and soft-start to reduce inrush current.
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 2.5±10% |
转速 Speed(RPM) | min-1 | 1900±5% |
功率消耗 Power consumption | W | 500±10% |
声压级 Sound Pressure Level | dB(A) | 76±5% |
最大风量 Max. Air Flow | CFM / m3/H | 971.025/1650 |
最大静压 Max. Static Pressure | In.wg /Pa | 2.8/700 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP54 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FF3G200-2AGL-20 is a high-performance EC centrifugal fan engineered for industrial ventilation and airflow management. Built with an external rotor brushless motor (BLEC102), it combines energy efficiency with precise speed control. Its forward-curved design generates robust airflow (up to 1650 m³/h) and static pressure (up to 700 Pa), ideal for confined or demanding systems. Featuring an IP54-rated housing, galvanized steel impeller, and wide operating temperature range, it delivers reliability in harsh environments.
Intelligent Motor & Wide Voltage Support
Operates stably across 184–270VAC input fluctuations. The integrated EC controller enables soft-start, prevents damage from voltage spikes/drops, motor overloads, or stalls, and includes reverse-polarity protection.
Industrial-Grade Control & Monitoring
Supports 0–10VDC or PWM speed control for seamless system integration. Provides real-time RPM feedback via tachometer (FG) output (5 pulses/revolution) and includes RS485 terminals (RSA/RSB) for optional MODBUS protocol upgrades.
Ruggedized Construction for Continuous Duty
Designed for 24/7 operation (S1 duty) with a galvanized steel impeller (200mm), die-cast aluminum housing, and ball bearings. Withstands temperatures from -25°C to +60°C and features IP54 dust/water resistance.
Industrial HVAC: Ventilation, exhaust, and air handling in factories, warehouses, and production floors.
Process Cooling: Thermal management for machinery, electrical cabinets, or industrial ovens.
Air Movement Systems: Fume extraction, drying tunnels, or energy recovery units requiring high static pressure.
Q1: Can the fan be installed vertically or upside-down?
Yes, it supports installation in any orientation.
Q2: What is the default control method?
Standard control uses 0–10VDC analog or PWM signals. RS485 MODBUS requires protocol activation (contact Fanova support).
Q3: How do I monitor fan speed?
Use the FG (tachometer) output wire (white), which emits 5 pulses per revolution.
Q4: What safety protections are included?
Protections cover over/under-voltage, motor overheating, locked rotors, reverse polarity, and soft-start to reduce inrush current.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |