Introducing the 230V EC Diameter 250mm Backward Centrifugal Fan, a cutting-edge option in the realm of centrifugal fans a, this model stands out for its remarkable efficiency and energy conservation. It encapsulates the essence of what makes the best centrifugal fans a truly exceptional choice for various applications.
High Efficiency: This centrifugal fan is designed to deliver impressive airflow rates and pressure, all while keeping energy consumption to a minimum. It ensures that users experience the best in performance and efficiency, making it a top pick among centrifugal fans a.
Low Noise: By harnessing the power of advanced fluid dynamics, the fan's blade angles are meticulously calibrated for superior airflow management. This meticulous design not only optimizes performance but also significantly reduces noise levels, setting it apart from other centrifugal blower fans.
Wide Application Range: Versatility is the name of the game with this centrifugal fan. It finds its place in a diverse array of industries and environments, such as industrial ventilation, HVAC systems, agriculture, construction, and automotive sectors. It offers adaptable, customized solutions, including OEM/ODM services, catering to the unique needs of each application.
Sustainable Development: With a commitment to sustainability, this centrifugal fan is crafted using innovative, eco-friendly materials like fiberglass-reinforced plastic. It not only meets stringent green energy standards but also stands up to tough working conditions, ensuring long-lasting reliability and durability.
Easy Installation and Maintenance: Designed with user convenience in mind, the fan comes with installation grilles and duct mounting options, simplifying the setup process. Its easily maintainable components make routine servicing a breeze, further enhancing its appeal in the market of centrifugal fans a.
Whether you're looking for a rooftop centrifugal exhaust fan - RTC for your building's ventilation needs or seeking the best centrifugal fans a for a specific industrial application, this 230V EC model checks all the boxes, offering a blend of performance, quiet operation, and sustainability that is hard to match.
Introducing the 230V EC Diameter 250mm Backward Centrifugal Fan, a cutting-edge option in the realm of centrifugal fans a, this model stands out for its remarkable efficiency and energy conservation. It encapsulates the essence of what makes the best centrifugal fans a truly exceptional choice for various applications.
High Efficiency: This centrifugal fan is designed to deliver impressive airflow rates and pressure, all while keeping energy consumption to a minimum. It ensures that users experience the best in performance and efficiency, making it a top pick among centrifugal fans a.
Low Noise: By harnessing the power of advanced fluid dynamics, the fan's blade angles are meticulously calibrated for superior airflow management. This meticulous design not only optimizes performance but also significantly reduces noise levels, setting it apart from other centrifugal blower fans.
Wide Application Range: Versatility is the name of the game with this centrifugal fan. It finds its place in a diverse array of industries and environments, such as industrial ventilation, HVAC systems, agriculture, construction, and automotive sectors. It offers adaptable, customized solutions, including OEM/ODM services, catering to the unique needs of each application.
Sustainable Development: With a commitment to sustainability, this centrifugal fan is crafted using innovative, eco-friendly materials like fiberglass-reinforced plastic. It not only meets stringent green energy standards but also stands up to tough working conditions, ensuring long-lasting reliability and durability.
Easy Installation and Maintenance: Designed with user convenience in mind, the fan comes with installation grilles and duct mounting options, simplifying the setup process. Its easily maintainable components make routine servicing a breeze, further enhancing its appeal in the market of centrifugal fans a.
Whether you're looking for a rooftop centrifugal exhaust fan - RTC for your building's ventilation needs or seeking the best centrifugal fans a for a specific industrial application, this 230V EC model checks all the boxes, offering a blend of performance, quiet operation, and sustainability that is hard to match.
Phase | ~ | 1~ |
Nominal Voltage | VAC | 230 |
Nominal voltage range | VAC | 184~270 |
Frequency | Hz | 50/60 |
Current draw | A | 1.6±10% |
Speed(RPM) | min-1 | 3550±5% |
Power consumption | W | 360±10% |
Sound Pressure Level | dB(A) | 82.6±5% |
Max. Air Flow | CFM / m3/H | 1155.81/1964 |
Max. Static Pressure | In.wg /Pa | 4.06/1016 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
Phase | ~ | 1~ |
Nominal Voltage | VAC | 230 |
Nominal voltage range | VAC | 184~270 |
Frequency | Hz | 50/60 |
Current draw | A | 1.6±10% |
Speed(RPM) | min-1 | 3550±5% |
Power consumption | W | 360±10% |
Sound Pressure Level | dB(A) | 82.6±5% |
Max. Air Flow | CFM / m3/H | 1155.81/1964 |
Max. Static Pressure | In.wg /Pa | 4.06/1016 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |