Availability: | |
---|---|
Quantity: | |
FS3G140-24GL-90
Fanova
Nominal Voltage | VDC | 24 |
Nominal voltage range | VDC | 16~28 |
Current draw | A | 6.25±10% |
Speed(RPM) | min-1 | 2560±5% |
Power consumption | W | 150±10% |
Sound Pressure Level | dB(A) | 70±5% |
Max. Air Flow | CFM / m3/H | 347.22/590 |
Max. Static Pressure | In.wg /Pa | 2.216/554 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
The FS3G140-24GL-90 is a high-performance single-inlet centrifugal DC fan engineered for demanding industrial ventilation and cooling applications. Featuring a brushless DC motor (BLDC92) and optimized aerodynamic design, it delivers robust airflow (up to 590 m³/h) and static pressure (554 Pa) while operating efficiently across a wide voltage range (16–28 VDC). Its compact form factor, industrial-grade certifications (CE, RoHS, ISO9001, ErP2015), and advanced protection systems make it suitable for harsh environments where reliability is critical.
Industrial-Grade Resilience
Operates reliably in temperatures from -25°C to 60°C with IP44-rated dust/water resistance. Ball bearings and hardened galvanized steel impellers ensure longevity (50,000 hours L10 life) under continuous operation (S1 duty cycle).
Intelligent Control & Protection
Supports 0–10VDC/PWM speed modulation with tachometer output (FG signal) for real-time RPM monitoring. Integrated safeguards include soft-start protection, reverse polarity lockout, and overload/undervoltage/overheat shutdown to prevent damage.
High-Efficiency Airflow
Generates significant static pressure (554 Pa max) for overcoming system resistance, ideal for confined spaces. The 38-blade impeller design maximizes air displacement (347 CFM) while maintaining low acoustic noise (70 dB(A)).
Industrial Equipment Cooling: CNC machinery, control cabinets, power converters.
HVAC Systems: Air handling units, ducted exhaust systems.
Outdoor/Portable Devices: Telecom shelters, mobile power generators, EV charging stations.
Automation & Robotics: Motor drives, laser cooling modules.
Q: Can the fan operate below 16VDC?
A: No. Undervoltage protection activates below 16VDC to prevent motor damage.
Q: Is reverse wiring preventable?
A: Yes. Reverse polarity protection halts operation if power/control lines are misconnected.
Q: What customization is available?
A: Cable length, communication protocols (beyond 0–10V/PWM), and voltage variants (contact technical support).
Q: Why avoid touching the impeller during startup?
A: Soft-start may delay rotation; accidental contact risks injury despite low initial speed.
Nominal Voltage | VDC | 24 |
Nominal voltage range | VDC | 16~28 |
Current draw | A | 6.25±10% |
Speed(RPM) | min-1 | 2560±5% |
Power consumption | W | 150±10% |
Sound Pressure Level | dB(A) | 70±5% |
Max. Air Flow | CFM / m3/H | 347.22/590 |
Max. Static Pressure | In.wg /Pa | 2.216/554 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
The FS3G140-24GL-90 is a high-performance single-inlet centrifugal DC fan engineered for demanding industrial ventilation and cooling applications. Featuring a brushless DC motor (BLDC92) and optimized aerodynamic design, it delivers robust airflow (up to 590 m³/h) and static pressure (554 Pa) while operating efficiently across a wide voltage range (16–28 VDC). Its compact form factor, industrial-grade certifications (CE, RoHS, ISO9001, ErP2015), and advanced protection systems make it suitable for harsh environments where reliability is critical.
Industrial-Grade Resilience
Operates reliably in temperatures from -25°C to 60°C with IP44-rated dust/water resistance. Ball bearings and hardened galvanized steel impellers ensure longevity (50,000 hours L10 life) under continuous operation (S1 duty cycle).
Intelligent Control & Protection
Supports 0–10VDC/PWM speed modulation with tachometer output (FG signal) for real-time RPM monitoring. Integrated safeguards include soft-start protection, reverse polarity lockout, and overload/undervoltage/overheat shutdown to prevent damage.
High-Efficiency Airflow
Generates significant static pressure (554 Pa max) for overcoming system resistance, ideal for confined spaces. The 38-blade impeller design maximizes air displacement (347 CFM) while maintaining low acoustic noise (70 dB(A)).
Industrial Equipment Cooling: CNC machinery, control cabinets, power converters.
HVAC Systems: Air handling units, ducted exhaust systems.
Outdoor/Portable Devices: Telecom shelters, mobile power generators, EV charging stations.
Automation & Robotics: Motor drives, laser cooling modules.
Q: Can the fan operate below 16VDC?
A: No. Undervoltage protection activates below 16VDC to prevent motor damage.
Q: Is reverse wiring preventable?
A: Yes. Reverse polarity protection halts operation if power/control lines are misconnected.
Q: What customization is available?
A: Cable length, communication protocols (beyond 0–10V/PWM), and voltage variants (contact technical support).
Q: Why avoid touching the impeller during startup?
A: Soft-start may delay rotation; accidental contact risks injury despite low initial speed.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |