Availability: | |
---|---|
Quantity: | |
FB3G355-4AAS-30
Fanova
相 Phase | ~ | 3~ |
额定电压 Nominal Voltage | VAC | 380 |
电压范围 Nominal voltage range | VAC | 304V~456V |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 1.7±10% |
转速 Speed(RPM) | min-1 | 2400±5% |
功率消耗 Power consumption | W | 990±10% |
声压级 Sound Pressure Level | dB(A) | 88±5% |
最大风量 Max. Air Flow | CFM / m3/H | 3860.56/6560 |
最大静压 Max. Static Pressure | In.wg /Pa | 4.32/1080 |
绝缘等级 Insulation class | ~ | Class |
防护等级 Degree of protection | ~ | IP54 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FB3G355-4AAS-30 is a high-power industrial EC centrifugal fan designed for heavy-duty ventilation in demanding environments. Operating on 380VAC three-phase power, it delivers exceptional airflow (6560 m³/h) and extreme static pressure (1080 Pa) – ideal for large-scale industrial systems requiring robust performance. Featuring an aluminum impeller and IP54-rated construction, it combines industrial durability with advanced control integration for automated applications.
Industrial-Grade Power
Engineered for 380VAC three-phase operation with wide voltage tolerance (304–456VAC). Generates massive 1080 Pa static pressure for overcoming high resistance in ducted systems or industrial processes.
Smart Motor Control
Integrated RS485 Modbus communication (RSA/RSB ports) alongside standard 0–10V/PWM control. Includes +10VDC output for signal pull-up and FG tachometer (5 pulses/rev) for real-time monitoring.
Heavy-Duty Construction
Full aluminum impeller and housing withstand harsh conditions. IP54 protection resists dust ingress and water splashes, suitable for factories, plants, or outdoor enclosures.
Enhanced Safety Compliance
Exceeds industrial standards with 1800VAC dielectric strength, leakage current protection (≤3.5mA), and alarm contacts (NC/COM) for system fault reporting. Class F insulation ensures reliability at high temperatures.
Industrial Process Cooling: High-pressure ventilation for furnaces, laser cutters, or industrial ovens.
Large HVAC Systems: Air handling units (AHUs), rooftop vents, or duct boosters.
Power Generation: Cooling for transformers, turbine rooms, or backup generator enclosures.
Manufacturing Equipment: Dust extraction, fume removal, or drying tunnels.
Q: Can it run on single-phase power?
A: No. Requires stable 380VAC three-phase supply (50/60Hz).
Q: How is Modbus RS485 implemented?
A: Use RSA (green) and RSB (purple) wires with standard Modbus RTU protocol. Refer to separate communication guide.
Q: What triggers the alarm contact (NC/COM)?
A: Activates during faults: overheat, locked rotor, or power anomaly.
Q: Is harmonic filtering required?
A: Complies with EN 61000-3-2/3-3. For sensitive grids, add external filters if distortion exceeds local standards.
Q: Can the +10VDC output power external sensors?
A: No. Limited to 1.1mA – use only as pull-up voltage for control signals.
相 Phase | ~ | 3~ |
额定电压 Nominal Voltage | VAC | 380 |
电压范围 Nominal voltage range | VAC | 304V~456V |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 1.7±10% |
转速 Speed(RPM) | min-1 | 2400±5% |
功率消耗 Power consumption | W | 990±10% |
声压级 Sound Pressure Level | dB(A) | 88±5% |
最大风量 Max. Air Flow | CFM / m3/H | 3860.56/6560 |
最大静压 Max. Static Pressure | In.wg /Pa | 4.32/1080 |
绝缘等级 Insulation class | ~ | Class |
防护等级 Degree of protection | ~ | IP54 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FB3G355-4AAS-30 is a high-power industrial EC centrifugal fan designed for heavy-duty ventilation in demanding environments. Operating on 380VAC three-phase power, it delivers exceptional airflow (6560 m³/h) and extreme static pressure (1080 Pa) – ideal for large-scale industrial systems requiring robust performance. Featuring an aluminum impeller and IP54-rated construction, it combines industrial durability with advanced control integration for automated applications.
Industrial-Grade Power
Engineered for 380VAC three-phase operation with wide voltage tolerance (304–456VAC). Generates massive 1080 Pa static pressure for overcoming high resistance in ducted systems or industrial processes.
Smart Motor Control
Integrated RS485 Modbus communication (RSA/RSB ports) alongside standard 0–10V/PWM control. Includes +10VDC output for signal pull-up and FG tachometer (5 pulses/rev) for real-time monitoring.
Heavy-Duty Construction
Full aluminum impeller and housing withstand harsh conditions. IP54 protection resists dust ingress and water splashes, suitable for factories, plants, or outdoor enclosures.
Enhanced Safety Compliance
Exceeds industrial standards with 1800VAC dielectric strength, leakage current protection (≤3.5mA), and alarm contacts (NC/COM) for system fault reporting. Class F insulation ensures reliability at high temperatures.
Industrial Process Cooling: High-pressure ventilation for furnaces, laser cutters, or industrial ovens.
Large HVAC Systems: Air handling units (AHUs), rooftop vents, or duct boosters.
Power Generation: Cooling for transformers, turbine rooms, or backup generator enclosures.
Manufacturing Equipment: Dust extraction, fume removal, or drying tunnels.
Q: Can it run on single-phase power?
A: No. Requires stable 380VAC three-phase supply (50/60Hz).
Q: How is Modbus RS485 implemented?
A: Use RSA (green) and RSB (purple) wires with standard Modbus RTU protocol. Refer to separate communication guide.
Q: What triggers the alarm contact (NC/COM)?
A: Activates during faults: overheat, locked rotor, or power anomaly.
Q: Is harmonic filtering required?
A: Complies with EN 61000-3-2/3-3. For sensitive grids, add external filters if distortion exceeds local standards.
Q: Can the +10VDC output power external sensors?
A: No. Limited to 1.1mA – use only as pull-up voltage for control signals.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |