Availability: | |
---|---|
Quantity: | |
FB3G190-48PY-70
Fanova
Nominal Voltage | VDC | 48 |
Nominal voltage range | VDC | 36~57 |
Current draw | A | 1.2±10% |
Speed(RPM) | min-1 | 2950±5% |
Power consumption | W | 57±10% |
Sound Pressure Level | dB(A) | 68±5% |
Max. Air Flow | CFM / m3/H | 365.46/621 |
Max. Static Pressure | In.wg /Pa | 1.612/403 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
The FB3G190-48PY-70 is a high-torque DC centrifugal fan engineered for precision cooling in 48V systems. With its oversized 190mm impeller and brushless DC motor, it delivers robust airflow (621 m³/h) at lower noise levels (68 dB(A)), making it ideal for applications where quiet operation and energy efficiency are critical. Built to industrial standards (IP44, CE/RoHS), it thrives in demanding environments from telecom cabinets to renewable energy systems.
48V DC-Optimized Efficiency
Operates flawlessly on 36–57V DC power sources (e.g., solar/battery systems), consuming just 57W at peak load.
Eliminates AC/DC conversion losses, reducing energy waste by up to 20% vs. AC fans.
Large-Impeller Quiet Operation
190mm fiberglass-reinforced impeller moves 621 m³/h air at 2,950 RPM – achieving higher flow with 40% lower noise than comparable industrial fans.
Precision-balanced rotor (G6.3) minimizes vibration for silent performance.
Plug-and-Play Industrial Controls
Simplified 4-wire interface supports 0–10V DC or PWM speed control with tachometer (FG) feedback.
Integrated reverse-polarity protection prevents damage from wiring errors.
Telecom/Server Racks: Cooling for 48V backup power systems and base stations.
Renewable Energy: Ventilation in solar inverters, battery storage enclosures.
Medical Equipment: Low-noise cooling for imaging devices or lab analyzers.
Electric Mobility: Battery thermal management in EVs/charging stations.
Q1: Can it run directly from solar panels without a voltage regulator?
A1: Yes. Its wide voltage range (36–57V DC) tolerates fluctuations common in solar/battery systems.
Q2: Why choose DC over AC for high-airflow applications?
A2: DC fans offer finer speed control, lower EMI, and higher efficiency in 48V ecosystems (e.g., data centers, EVs).
Q3: Is it compatible with existing AC fan controllers?
A3: No. Requires a DC-compatible PWM or 0–10V controller (e.g., BMS interfaces).
Nominal Voltage | VDC | 48 |
Nominal voltage range | VDC | 36~57 |
Current draw | A | 1.2±10% |
Speed(RPM) | min-1 | 2950±5% |
Power consumption | W | 57±10% |
Sound Pressure Level | dB(A) | 68±5% |
Max. Air Flow | CFM / m3/H | 365.46/621 |
Max. Static Pressure | In.wg /Pa | 1.612/403 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
The FB3G190-48PY-70 is a high-torque DC centrifugal fan engineered for precision cooling in 48V systems. With its oversized 190mm impeller and brushless DC motor, it delivers robust airflow (621 m³/h) at lower noise levels (68 dB(A)), making it ideal for applications where quiet operation and energy efficiency are critical. Built to industrial standards (IP44, CE/RoHS), it thrives in demanding environments from telecom cabinets to renewable energy systems.
48V DC-Optimized Efficiency
Operates flawlessly on 36–57V DC power sources (e.g., solar/battery systems), consuming just 57W at peak load.
Eliminates AC/DC conversion losses, reducing energy waste by up to 20% vs. AC fans.
Large-Impeller Quiet Operation
190mm fiberglass-reinforced impeller moves 621 m³/h air at 2,950 RPM – achieving higher flow with 40% lower noise than comparable industrial fans.
Precision-balanced rotor (G6.3) minimizes vibration for silent performance.
Plug-and-Play Industrial Controls
Simplified 4-wire interface supports 0–10V DC or PWM speed control with tachometer (FG) feedback.
Integrated reverse-polarity protection prevents damage from wiring errors.
Telecom/Server Racks: Cooling for 48V backup power systems and base stations.
Renewable Energy: Ventilation in solar inverters, battery storage enclosures.
Medical Equipment: Low-noise cooling for imaging devices or lab analyzers.
Electric Mobility: Battery thermal management in EVs/charging stations.
Q1: Can it run directly from solar panels without a voltage regulator?
A1: Yes. Its wide voltage range (36–57V DC) tolerates fluctuations common in solar/battery systems.
Q2: Why choose DC over AC for high-airflow applications?
A2: DC fans offer finer speed control, lower EMI, and higher efficiency in 48V ecosystems (e.g., data centers, EVs).
Q3: Is it compatible with existing AC fan controllers?
A3: No. Requires a DC-compatible PWM or 0–10V controller (e.g., BMS interfaces).
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |