Availability: | |
---|---|
Quantity: | |
FB3G250-24PL-90
Fanova
Nominal Voltage | VDC | 24 |
Nominal voltage range | VDC | 16~28 |
Current draw | A | 3.5±10% |
Speed(RPM) | min-1 | 2150±5% |
Power consumption | W | 85±10% |
Sound Pressure Level | dB(A) | 66±5% |
Max. Air Flow | CFM / m3/H | 666.18/1132 |
Max. Static Pressure | In.wg /Pa | 2.032/508 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
The FB3G250-24PL-90 is a high-volume 24V DC centrifugal blower engineered for large-scale thermal management. Featuring a 250mm glass-fiber-reinforced impeller and robust BLDC92 motor, it delivers exceptional airflow for industrial ventilation, cooling systems, and heavy-duty exhaust applications where space allows.
Massive Airflow Capacity
Moves 1,132 m³/h (666 CFM) – ideal for high-volume cooling in large enclosures, ducted systems, or industrial exhausts.
Wide Voltage Tolerance
Operates reliably at 16–28VDC (±33% range), ensuring stability in fluctuating power environments (e.g., mobile equipment).
High-Resolution Monitoring
FG tach output delivers 4 pulses/revolution (white wire) for precise RPM tracking and early fault detection.
Heavy-Duty Endurance
Ball bearings, IP44 sealing, and 50k-hour lifespan withstand continuous operation in factories, workshops, or dusty settings.
Large Industrial Cabinets: Cooling high-density server racks, power distribution units (PDUs), and CNC machinery control panels.
HVAC & Ventilation: High-capacity air handlers, warehouse exhaust systems, industrial dryer cooling.
Process Cooling: Fume extraction in welding/painting bays, plastic injection molding machine ventilation.
Renewable Energy: Thermal management for wind turbine converters or large solar inverter banks.
Agriculture/Tech: Greenhouse airflow systems, data center hot-aisle containment.
Q: What makes this fan suitable for unstable power sources?
A: Its 16–28VDC range (±33%) compensates for voltage drops in generators, batteries, or long cable runs.
Q: How does the tach signal help maintenance?
A: The 4-pulse/rev FG output (white wire) provides finer RPM resolution for predictive diagnostics.
Q: Can it handle corrosive environments?
A: While IP44-rated against dust/splashes, chemically aggressive settings require custom housing.
Nominal Voltage | VDC | 24 |
Nominal voltage range | VDC | 16~28 |
Current draw | A | 3.5±10% |
Speed(RPM) | min-1 | 2150±5% |
Power consumption | W | 85±10% |
Sound Pressure Level | dB(A) | 66±5% |
Max. Air Flow | CFM / m3/H | 666.18/1132 |
Max. Static Pressure | In.wg /Pa | 2.032/508 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
The FB3G250-24PL-90 is a high-volume 24V DC centrifugal blower engineered for large-scale thermal management. Featuring a 250mm glass-fiber-reinforced impeller and robust BLDC92 motor, it delivers exceptional airflow for industrial ventilation, cooling systems, and heavy-duty exhaust applications where space allows.
Massive Airflow Capacity
Moves 1,132 m³/h (666 CFM) – ideal for high-volume cooling in large enclosures, ducted systems, or industrial exhausts.
Wide Voltage Tolerance
Operates reliably at 16–28VDC (±33% range), ensuring stability in fluctuating power environments (e.g., mobile equipment).
High-Resolution Monitoring
FG tach output delivers 4 pulses/revolution (white wire) for precise RPM tracking and early fault detection.
Heavy-Duty Endurance
Ball bearings, IP44 sealing, and 50k-hour lifespan withstand continuous operation in factories, workshops, or dusty settings.
Large Industrial Cabinets: Cooling high-density server racks, power distribution units (PDUs), and CNC machinery control panels.
HVAC & Ventilation: High-capacity air handlers, warehouse exhaust systems, industrial dryer cooling.
Process Cooling: Fume extraction in welding/painting bays, plastic injection molding machine ventilation.
Renewable Energy: Thermal management for wind turbine converters or large solar inverter banks.
Agriculture/Tech: Greenhouse airflow systems, data center hot-aisle containment.
Q: What makes this fan suitable for unstable power sources?
A: Its 16–28VDC range (±33%) compensates for voltage drops in generators, batteries, or long cable runs.
Q: How does the tach signal help maintenance?
A: The 4-pulse/rev FG output (white wire) provides finer RPM resolution for predictive diagnostics.
Q: Can it handle corrosive environments?
A: While IP44-rated against dust/splashes, chemically aggressive settings require custom housing.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |