Nominal Voltage | VDC | 48 |
Nominal voltage range | VDC | 36~57 |
Current draw | A | 1.7±10% |
Speed(RPM) | min-1 | 1800±5% |
Power consumption | W | 80±10% |
Sound Pressure Level | dB(A) | 66±5% |
Max. Air Flow | CFM / m3/H | 1353.55/2300 |
Max. Static Pressure | In.wg /Pa | 0.68/170 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
The FW3G300-48PC-90 is a duct-optimized axial DC fan engineered for high-volume ventilation. Featuring a 300mm glass-fiber-reinforced impeller and integrated wall ring, it delivers 2300 m³/h airflow at just 66 dB(A) noise. Powered by a 48V DC motor (BLDC92), it consumes 80W with IP44 protection and operates continuously (S1 duty) in -25℃ to 60℃ environments.
Duct-Ready Airflow Design
The integrated wall ring minimizes turbulence, enabling straight-airflow efficiency for ducts or enclosures with low static pressure (170 Pa).
Lightweight Composite Impeller
5-blade PP+GF construction reduces inertia for faster response while resisting corrosion in humid environments.
Reverse-Rotation Optimization
Anticlockwise spin (viewed toward rotor) simplifies integration in confined spaces where standard clockwise fans cause airflow conflict.
Ultra-Low Power Profile
Draws just 1.7A at 48VDC—ideal for solar/battery systems—with soft-start protection to prevent surge currents.
Cabinet & Tunnel Ventilation: Server racks, control panels, and agricultural tunnels requiring directional airflow.
EV Battery Cooling: Low-static-pressure cooling in electric vehicles/mobile machinery.
Energy-Efficient Exhaust: Parking garages, workshops where 66 dB(A) noise meets strict acoustic standards.
Q1: Why anticlockwise rotation?
A: Allows mirrored installation vs. standard fans. Critical when space constraints prevent duct redesign—verify rotation mark on housing.
Q2: Can the wall ring be removed?
A: No. Its aerodynamic profile is integral to performance. Removal causes 15-20% airflow loss.
Q3: Is plastic impeller durable at 60°C?
A: Yes. Glass-fiber reinforcement ensures stability ≤85°C (electronics limit). Avoid direct UV exposure.
Q4: How to handle wiring for reverse polarity?
A: Blue wire must connect to control GND. Reversing with power (red) triggers protection shutdown.
Q5: Compatible with speed controllers?
A: Yes. Yellow wire accepts 0-10V/PWM. FG output (white) gives 4 pulses/rev for RPM feedback.
Nominal Voltage | VDC | 48 |
Nominal voltage range | VDC | 36~57 |
Current draw | A | 1.7±10% |
Speed(RPM) | min-1 | 1800±5% |
Power consumption | W | 80±10% |
Sound Pressure Level | dB(A) | 66±5% |
Max. Air Flow | CFM / m3/H | 1353.55/2300 |
Max. Static Pressure | In.wg /Pa | 0.68/170 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
The FW3G300-48PC-90 is a duct-optimized axial DC fan engineered for high-volume ventilation. Featuring a 300mm glass-fiber-reinforced impeller and integrated wall ring, it delivers 2300 m³/h airflow at just 66 dB(A) noise. Powered by a 48V DC motor (BLDC92), it consumes 80W with IP44 protection and operates continuously (S1 duty) in -25℃ to 60℃ environments.
Duct-Ready Airflow Design
The integrated wall ring minimizes turbulence, enabling straight-airflow efficiency for ducts or enclosures with low static pressure (170 Pa).
Lightweight Composite Impeller
5-blade PP+GF construction reduces inertia for faster response while resisting corrosion in humid environments.
Reverse-Rotation Optimization
Anticlockwise spin (viewed toward rotor) simplifies integration in confined spaces where standard clockwise fans cause airflow conflict.
Ultra-Low Power Profile
Draws just 1.7A at 48VDC—ideal for solar/battery systems—with soft-start protection to prevent surge currents.
Cabinet & Tunnel Ventilation: Server racks, control panels, and agricultural tunnels requiring directional airflow.
EV Battery Cooling: Low-static-pressure cooling in electric vehicles/mobile machinery.
Energy-Efficient Exhaust: Parking garages, workshops where 66 dB(A) noise meets strict acoustic standards.
Q1: Why anticlockwise rotation?
A: Allows mirrored installation vs. standard fans. Critical when space constraints prevent duct redesign—verify rotation mark on housing.
Q2: Can the wall ring be removed?
A: No. Its aerodynamic profile is integral to performance. Removal causes 15-20% airflow loss.
Q3: Is plastic impeller durable at 60°C?
A: Yes. Glass-fiber reinforcement ensures stability ≤85°C (electronics limit). Avoid direct UV exposure.
Q4: How to handle wiring for reverse polarity?
A: Blue wire must connect to control GND. Reversing with power (red) triggers protection shutdown.
Q5: Compatible with speed controllers?
A: Yes. Yellow wire accepts 0-10V/PWM. FG output (white) gives 4 pulses/rev for RPM feedback.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |