| Availability: | |
|---|---|
| Quantity: | |
FB3G225-2APY-70
Fanova
Phase | ~ | 1~ |
Nominal Voltage | VAC | 230 |
Nominal voltage range | VAC | 184~270 |
Frequency | Hz | 50/60 |
Current draw | A | 0.72±10% |
Speed(RPM) | min-1 | 2500±5% |
Power consumption | W | 120±10% |
Sound Pressure Level | dB(A) | 71±5% |
Max. Air Flow | CFM / m3/H | 646.17/1098 |
Max. Static Pressure | In.wg /Pa | 1.79/447 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
The FB3G225-2APY-70 is an energy-efficient single-phase AC centrifugal fan designed for residential and light commercial ventilation. Featuring a glass-fiber-reinforced plastic impeller and EC motor (Model: BLEC72), it delivers quiet operation (71 dB(A)) and robust airflow (1,098 m³/h) at 230V AC. Ideal for applications requiring compact yet powerful airflow with standard household voltage compatibility.
Single-Phase AC Efficiency
Operates on standard 230V AC (184–270V range) with low power consumption (120W), eliminating need for DC converters and simplifying integration into existing systems.
Lightweight & Low-Noise Design
Reinforced plastic impeller reduces weight/vibration, enabling quieter performance at 2,500 RPM—suitable for noise-sensitive environments.
Integrated Control Flexibility
Built-in +10VDC output powers external sensors/speed controllers. Supports PWM/0–10VDC input for dynamic speed adjustments.
Residential Ventilation: Bathroom exhausts, kitchen hoods, attic fans.
Light Commercial: Server closets, small workshops, retail display cooling.
HVAC Auxiliaries: Air curtain units, duct boosters.
Q1: Can it run on 110V/120V systems?
A: No—designed exclusively for 230V AC. Use a step-up transformer for 110V regions.
Q2: Is the +10VDC output protected?
A: Yes—max 1.1mA current limit; always use a series resistor when connecting to external circuits.
Q3: Why choose plastic over metal impellers?
A: Lower inertia reduces startup energy and noise while maintaining corrosion resistance.
Q4: How is motor lifespan ensured?
A: Sealed ball bearings (50,000-hour L10 life) and thermal protection prevent overload damage.
Phase | ~ | 1~ |
Nominal Voltage | VAC | 230 |
Nominal voltage range | VAC | 184~270 |
Frequency | Hz | 50/60 |
Current draw | A | 0.72±10% |
Speed(RPM) | min-1 | 2500±5% |
Power consumption | W | 120±10% |
Sound Pressure Level | dB(A) | 71±5% |
Max. Air Flow | CFM / m3/H | 646.17/1098 |
Max. Static Pressure | In.wg /Pa | 1.79/447 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
The FB3G225-2APY-70 is an energy-efficient single-phase AC centrifugal fan designed for residential and light commercial ventilation. Featuring a glass-fiber-reinforced plastic impeller and EC motor (Model: BLEC72), it delivers quiet operation (71 dB(A)) and robust airflow (1,098 m³/h) at 230V AC. Ideal for applications requiring compact yet powerful airflow with standard household voltage compatibility.
Single-Phase AC Efficiency
Operates on standard 230V AC (184–270V range) with low power consumption (120W), eliminating need for DC converters and simplifying integration into existing systems.
Lightweight & Low-Noise Design
Reinforced plastic impeller reduces weight/vibration, enabling quieter performance at 2,500 RPM—suitable for noise-sensitive environments.
Integrated Control Flexibility
Built-in +10VDC output powers external sensors/speed controllers. Supports PWM/0–10VDC input for dynamic speed adjustments.
Residential Ventilation: Bathroom exhausts, kitchen hoods, attic fans.
Light Commercial: Server closets, small workshops, retail display cooling.
HVAC Auxiliaries: Air curtain units, duct boosters.
Q1: Can it run on 110V/120V systems?
A: No—designed exclusively for 230V AC. Use a step-up transformer for 110V regions.
Q2: Is the +10VDC output protected?
A: Yes—max 1.1mA current limit; always use a series resistor when connecting to external circuits.
Q3: Why choose plastic over metal impellers?
A: Lower inertia reduces startup energy and noise while maintaining corrosion resistance.
Q4: How is motor lifespan ensured?
A: Sealed ball bearings (50,000-hour L10 life) and thermal protection prevent overload damage.




| Voltage Output | Output +10VDC, max. 1.1 mA (Can be used as speed control input voltage or FG signal pull-up voltage,and need to be circumscribed in series with a pull -up resister, details as connection diagram.) | |
| Dielectric Resistance | 10mA maximum at 1800VAC 50Hz one second Between frame and (+) terminal | |
| Life Expectance | 50,000 Hours(L10) | |
| Leakage Current | ≤3.5mA (Max. ) | |
| Direction of Air Flow | All around,Straight forward from air outlet | |
| Motor | External rotor EC motor | |
| Technical features | Motor current limitation | |
| Soft starting Protection | ||
| Under/Over voltage detection | ||
| Thermal overload protection for electronics/motor | ||
| Line undervoltage detection | ||
| Locked-rotor Protection | ||
| Reverse Polarity Protection | ||
| Operating Temperature | -25ºC (Min. ) | 60ºC (Max. ) |
| Heat sink of IC | 115ºC (Max. ) | |
| Other electronic parts | 85ºC (Max. ) | |
| Ball bering | 80ºC (Max. ) | |
| Lead Wire | 120ºC (Max. ) | |
| Storage Temperature | -40ºC to 75ºC | |
| Operating Humidity | 5% to 90% RH | |
| Storage Humidity | 5% to 95% RH | |
| Electronics housing material | Die-cast aluminum | |
| Operation Mode | S1 | |
| Motor bearing | Ball bearing | |
| Valid For Approval/Standard | CE,RoHS,ErP2015 | |
| Voltage Output | Output +10VDC, max. 1.1 mA (Can be used as speed control input voltage or FG signal pull-up voltage,and need to be circumscribed in series with a pull -up resister, details as connection diagram.) | |
| Dielectric Resistance | 10mA maximum at 1800VAC 50Hz one second Between frame and (+) terminal | |
| Life Expectance | 50,000 Hours(L10) | |
| Leakage Current | ≤3.5mA (Max. ) | |
| Direction of Air Flow | All around,Straight forward from air outlet | |
| Motor | External rotor EC motor | |
| Technical features | Motor current limitation | |
| Soft starting Protection | ||
| Under/Over voltage detection | ||
| Thermal overload protection for electronics/motor | ||
| Line undervoltage detection | ||
| Locked-rotor Protection | ||
| Reverse Polarity Protection | ||
| Operating Temperature | -25ºC (Min. ) | 60ºC (Max. ) |
| Heat sink of IC | 115ºC (Max. ) | |
| Other electronic parts | 85ºC (Max. ) | |
| Ball bering | 80ºC (Max. ) | |
| Lead Wire | 120ºC (Max. ) | |
| Storage Temperature | -40ºC to 75ºC | |
| Operating Humidity | 5% to 90% RH | |
| Storage Humidity | 5% to 95% RH | |
| Electronics housing material | Die-cast aluminum | |
| Operation Mode | S1 | |
| Motor bearing | Ball bearing | |
| Valid For Approval/Standard | CE,RoHS,ErP2015 | |