Availability: | |
---|---|
Quantity: | |
FB3G220-110PY-90
Fanova
Nominal Voltage | VDC | 110 |
Nominal voltage range | VDC | 88~132 |
Current draw | A | 1.6±10% |
Speed(RPM) | min-1 | 3550±5% |
Power consumption | W | 175±10% |
Sound Pressure Level | dB(A) | 76±5% |
Max. Air Flow | CFM / m3/H | 647.35/1100 |
Max. Static Pressure | In.wg /Pa | 3.28/820 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
Product Overview
The FB3G220-110PY-90 is a high-pressure DC centrifugal blower engineered for demanding ventilation applications requiring robust static pressure performance. Featuring a reinforced composite impeller and 110VDC operation, it delivers efficient airflow in industrial systems where precise pressure control and compact power are essential.
Core Features
Turbo-Pressure Performance
Generates exceptional 820 Pa static pressure – significantly higher than standard DC fans – enabling effective airflow in restricted duct systems and high-resistance environments.
Optimized Acoustic Profile
Maintains low 76 dB(A) noise levels at 3550 RPM through precision-balanced backward-curved blades, making it suitable for noise-sensitive installations.
Industrial-Ready Construction
Features glass-fiber reinforced plastic impeller and die-cast aluminum housing for durability in continuous-duty applications (-25°C to 60°C).
High-Speed DC Control
Operates on 110VDC (88-132V range) with PWM/0-10V input and tachometer output (4 pulses/revolution) for precise speed regulation.
Applications
Industrial Process Ventilation: Fume extraction in welding stations, chemical processing, and powder handling
Drying Systems: High-pressure airflow for industrial ovens, printing equipment, and textile processing
Material Handling: Pneumatic conveying of lightweight materials in production lines
Electronics Manufacturing: Cooling laser cutters, PCB assembly machines, and SMT reflow ovens
Test Chamber Ventilation: Environmental simulation units requiring precise pressure control.
FAQ
Q1: Can this fan replace my existing 115VAC centrifugal blower?
A: Yes, its 88-132VDC operating range is compatible with 115VAC rectified systems. Ensure your power supply delivers stable DC output within this voltage band.
Q2: Why choose 110VDC over standard 24VDC/48VDC fans?
A: 110VDC enables higher static pressure (820 Pa) with lower current draw (1.6A), reducing wiring costs and voltage drop in long-distance installations.
Q3: How does the 4-pulse FG signal benefit my system?
A: The tachometer output (4 pulses/revolution) allows real-time RPM monitoring for predictive maintenance and closed-loop speed control in automated setups.
Nominal Voltage | VDC | 110 |
Nominal voltage range | VDC | 88~132 |
Current draw | A | 1.6±10% |
Speed(RPM) | min-1 | 3550±5% |
Power consumption | W | 175±10% |
Sound Pressure Level | dB(A) | 76±5% |
Max. Air Flow | CFM / m3/H | 647.35/1100 |
Max. Static Pressure | In.wg /Pa | 3.28/820 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
Product Overview
The FB3G220-110PY-90 is a high-pressure DC centrifugal blower engineered for demanding ventilation applications requiring robust static pressure performance. Featuring a reinforced composite impeller and 110VDC operation, it delivers efficient airflow in industrial systems where precise pressure control and compact power are essential.
Core Features
Turbo-Pressure Performance
Generates exceptional 820 Pa static pressure – significantly higher than standard DC fans – enabling effective airflow in restricted duct systems and high-resistance environments.
Optimized Acoustic Profile
Maintains low 76 dB(A) noise levels at 3550 RPM through precision-balanced backward-curved blades, making it suitable for noise-sensitive installations.
Industrial-Ready Construction
Features glass-fiber reinforced plastic impeller and die-cast aluminum housing for durability in continuous-duty applications (-25°C to 60°C).
High-Speed DC Control
Operates on 110VDC (88-132V range) with PWM/0-10V input and tachometer output (4 pulses/revolution) for precise speed regulation.
Applications
Industrial Process Ventilation: Fume extraction in welding stations, chemical processing, and powder handling
Drying Systems: High-pressure airflow for industrial ovens, printing equipment, and textile processing
Material Handling: Pneumatic conveying of lightweight materials in production lines
Electronics Manufacturing: Cooling laser cutters, PCB assembly machines, and SMT reflow ovens
Test Chamber Ventilation: Environmental simulation units requiring precise pressure control.
FAQ
Q1: Can this fan replace my existing 115VAC centrifugal blower?
A: Yes, its 88-132VDC operating range is compatible with 115VAC rectified systems. Ensure your power supply delivers stable DC output within this voltage band.
Q2: Why choose 110VDC over standard 24VDC/48VDC fans?
A: 110VDC enables higher static pressure (820 Pa) with lower current draw (1.6A), reducing wiring costs and voltage drop in long-distance installations.
Q3: How does the 4-pulse FG signal benefit my system?
A: The tachometer output (4 pulses/revolution) allows real-time RPM monitoring for predictive maintenance and closed-loop speed control in automated setups.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |