Availability: | |
---|---|
Quantity: | |
FB3G220-110PY-90
Fanova
Nominal Voltage | VDC | 110 |
Nominal voltage range | VDC | 88~132 |
Current draw | A | 1.6±10% |
Speed(RPM) | min-1 | 3550±5% |
Power consumption | W | 175±10% |
Sound Pressure Level | dB(A) | 76±5% |
Max. Air Flow | CFM / m3/H | 647.35/1100 |
Max. Static Pressure | In.wg /Pa | 3.28/820 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
The FB3G220-110PY-90 is a compact DC centrifugal fan engineered for high-pressure airflow in space-constrained systems. Operating at 110VDC with reinforced fiberglass impellers, it delivers exceptional static pressure (820 Pa) at 3,550 RPM — ideal for applications demanding silent, efficient cooling without AC power infrastructure. IP44-rated and CE-certified, it excels in precision equipment where reliability is non-negotiable.
High-Pressure DC Powerhouse
Generates industrial-grade static pressure (820 Pa) from a 110VDC input — eliminates AC/DC converters and simplifies integration into DC-based systems.
Compact Force Multiplier
Squeezes 7-blade aerodynamic performance into a 220mm footprint, leveraging fiberglass-reinforced plastic for lightweight durability at 3,550 RPM.
Silent & Stable
Maintains sub-76 dB(A) noise levels despite high RPMs, with soft-start protection preventing mechanical stress during power cycles.
Medical Devices: MRI cooling, dental vacuum systems, lab analyzers.
Transportation: Electric vehicle battery thermal management, rail HVAC.
Precision Instruments: 3D printers, laser cutters, semiconductor testers.
Renewable Energy: DC-coupled solar inverters, wind turbine control cabinets.
Q: Why 110VDC instead of 24/48V?
A: Higher voltage reduces current draw (1.6A max), enabling thinner wires and longer cable runs without power loss.
Q: Can it replace AC fans in existing setups?
A: Only with a DC power source. Pair with a 230VAC/110VDC converter if AC mains are unavoidable.
Q: Is the plastic impeller durable at 3,550 RPM?
A: Yes — glass fiber reinforcement prevents deformation. Avoid abrasive particulates.
Q: Why fewer wires than other models?
A: Simplified DC design needs only power/control/FG wires — faster installation, lower error risk.
Nominal Voltage | VDC | 110 |
Nominal voltage range | VDC | 88~132 |
Current draw | A | 1.6±10% |
Speed(RPM) | min-1 | 3550±5% |
Power consumption | W | 175±10% |
Sound Pressure Level | dB(A) | 76±5% |
Max. Air Flow | CFM / m3/H | 647.35/1100 |
Max. Static Pressure | In.wg /Pa | 3.28/820 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
The FB3G220-110PY-90 is a compact DC centrifugal fan engineered for high-pressure airflow in space-constrained systems. Operating at 110VDC with reinforced fiberglass impellers, it delivers exceptional static pressure (820 Pa) at 3,550 RPM — ideal for applications demanding silent, efficient cooling without AC power infrastructure. IP44-rated and CE-certified, it excels in precision equipment where reliability is non-negotiable.
High-Pressure DC Powerhouse
Generates industrial-grade static pressure (820 Pa) from a 110VDC input — eliminates AC/DC converters and simplifies integration into DC-based systems.
Compact Force Multiplier
Squeezes 7-blade aerodynamic performance into a 220mm footprint, leveraging fiberglass-reinforced plastic for lightweight durability at 3,550 RPM.
Silent & Stable
Maintains sub-76 dB(A) noise levels despite high RPMs, with soft-start protection preventing mechanical stress during power cycles.
Medical Devices: MRI cooling, dental vacuum systems, lab analyzers.
Transportation: Electric vehicle battery thermal management, rail HVAC.
Precision Instruments: 3D printers, laser cutters, semiconductor testers.
Renewable Energy: DC-coupled solar inverters, wind turbine control cabinets.
Q: Why 110VDC instead of 24/48V?
A: Higher voltage reduces current draw (1.6A max), enabling thinner wires and longer cable runs without power loss.
Q: Can it replace AC fans in existing setups?
A: Only with a DC power source. Pair with a 230VAC/110VDC converter if AC mains are unavoidable.
Q: Is the plastic impeller durable at 3,550 RPM?
A: Yes — glass fiber reinforcement prevents deformation. Avoid abrasive particulates.
Q: Why fewer wires than other models?
A: Simplified DC design needs only power/control/FG wires — faster installation, lower error risk.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |