相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 1.35±10% |
转速 Speed(RPM) | min-1 | 2300±5% |
功率消耗 Power consumption | W | 170±10% |
声压级 Sound Pressure Level | dB(A) | 64±5% |
最大风量 Max. Air Flow | CFM / m3/H | 1859.66/3160 |
最大静压 Max. Static Pressure | In.wg /Pa | 0.84/210 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP44 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FG3G300-2APL-90 is a rugged EC axial fan with integrated safety grille, designed for heavy-duty industrial cooling and ventilation. Built around a brushless external rotor motor, it prioritizes energy efficiency, operational safety, and seamless integration into automated systems. Ideal for harsh environments, it meets strict EU standards (CE/ErP/RoHS) while minimizing maintenance needs.
Plug-and-Play Resilience
Thrives in unstable power grids (184–270 VAC) and extreme temperatures (-25°C to 60°C) with self-protection against voltage spikes, overheating, or motor jams — no external stabilizers needed.
Smart Control Ready
Accepts 0–10 VDC or PWM speed signals out-of-the-box, while the tachometer (FG) outputs real-time RPM data for predictive maintenance or system sync.
Safety by Default
The welded steel guard grille prevents accidental contact, while soft-start technology eliminates mechanical stress during power-up — critical for high-inertia systems.
Industrial Machinery: Cooling CNC equipment, laser cutters, or hydraulic power units.
Energy Infrastructure: Ventilation for solar inverters, battery cabinets, or transformer rooms.
Building Automation: Ducted HVAC exhausts, server room airflow management.
Noise-Sensitive Sites: Libraries, labs, or medical enclosures (sub-65 dB(A) operation).
Q: Can the guard grille be removed for higher airflow?
A: No — it’s safety-certified as a non-removable component. Tampering voids compliance.
Q: Does the fan require a controller to run?
A: Runs at full speed by default. Attach a 0–10V/PWM device only if adjustable speed is needed.
Q: Is the white (FG) wire mandatory?
A: Optional. Use it solely for monitoring RPM (e.g., fault detection).
Q: Can it handle dusty environments?
A: IP44 resists airborne particles but avoid direct dust blasts. Pair with filters in extreme cases.
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 1.35±10% |
转速 Speed(RPM) | min-1 | 2300±5% |
功率消耗 Power consumption | W | 170±10% |
声压级 Sound Pressure Level | dB(A) | 64±5% |
最大风量 Max. Air Flow | CFM / m3/H | 1859.66/3160 |
最大静压 Max. Static Pressure | In.wg /Pa | 0.84/210 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP44 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FG3G300-2APL-90 is a rugged EC axial fan with integrated safety grille, designed for heavy-duty industrial cooling and ventilation. Built around a brushless external rotor motor, it prioritizes energy efficiency, operational safety, and seamless integration into automated systems. Ideal for harsh environments, it meets strict EU standards (CE/ErP/RoHS) while minimizing maintenance needs.
Plug-and-Play Resilience
Thrives in unstable power grids (184–270 VAC) and extreme temperatures (-25°C to 60°C) with self-protection against voltage spikes, overheating, or motor jams — no external stabilizers needed.
Smart Control Ready
Accepts 0–10 VDC or PWM speed signals out-of-the-box, while the tachometer (FG) outputs real-time RPM data for predictive maintenance or system sync.
Safety by Default
The welded steel guard grille prevents accidental contact, while soft-start technology eliminates mechanical stress during power-up — critical for high-inertia systems.
Industrial Machinery: Cooling CNC equipment, laser cutters, or hydraulic power units.
Energy Infrastructure: Ventilation for solar inverters, battery cabinets, or transformer rooms.
Building Automation: Ducted HVAC exhausts, server room airflow management.
Noise-Sensitive Sites: Libraries, labs, or medical enclosures (sub-65 dB(A) operation).
Q: Can the guard grille be removed for higher airflow?
A: No — it’s safety-certified as a non-removable component. Tampering voids compliance.
Q: Does the fan require a controller to run?
A: Runs at full speed by default. Attach a 0–10V/PWM device only if adjustable speed is needed.
Q: Is the white (FG) wire mandatory?
A: Optional. Use it solely for monitoring RPM (e.g., fault detection).
Q: Can it handle dusty environments?
A: IP44 resists airborne particles but avoid direct dust blasts. Pair with filters in extreme cases.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |