FG3G350-2APL-20带网罩
Fanova
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 2.0±10% |
转速 Speed(RPM) | min-1 | 2000±5% |
功率消耗 Power consumption | W | 460±10% |
声压级 Sound Pressure Level | dB(A) | 80±5% |
最大风量 Max. Air Flow | CFM / m3/H | 2736.525/4650 |
最大静压 Max. Static Pressure | In.wg /Pa | 1.1/275 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP54 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FG3G350-2APL-20 is a high-capacity axial fan with an integrated safety grille, engineered for industrial ventilation where robust airflow (4650 m³/h) and operator protection are critical. Powered by a brushless EC motor (BLEC102) and featuring fiberglass-reinforced plastic blades, it combines corrosion resistance with IP54-rated dust/moisture protection. Ideal for harsh environments like factories or agricultural facilities.
Safety-First Grille Design
Integrated steel grille prevents accidental contact with blades—essential for OSHA-compliant installations in high-traffic areas. Maintains 4650 m³/h airflow without compromising safety.
Corrosion-Resistant Construction
Fiberglass-reinforced impeller withstands chemical exposure and humidity, outperforming standard plastics in agricultural/industrial settings. Aluminum housing adds structural rigidity.
Smart Industrial Connectivity
Features RS485 Modbus (via RSA/RSB wires) for centralized control and dry-contact alarms (NC/COM) to trigger safety shutdowns during faults. Includes 0–10VDC/PWM speed input and FG tachometer (5 pulses/rev).
Factory Floor Ventilation: Fume extraction in welding shops or chemical plants.
Grain Handling Systems: Dust-prone environments requiring spark-resistant components.
Wastewater Treatment: Corrosion-resistant airflow for aeration basins or pump rooms.
Q1: Can the grille be removed for cleaning?
No—it’s permanently fixed for safety. Clean externally using low-pressure air or a soft brush.
Q2: How do Modbus controls improve operations?
Use RSA (Green)/RSB (Purple) wires to daisy-chain fans, enabling speed synchronization and real-time diagnostics from a central HMI.
Q3: What triggers the alarm contacts (NC/COM)?
They close during motor overload, bearing failure, or blockage—sending signals to PLCs for automated responses.
Q4: Is this fan suitable for explosive environments?
No. For ATEX zones, request our intrinsically safe models.
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 2.0±10% |
转速 Speed(RPM) | min-1 | 2000±5% |
功率消耗 Power consumption | W | 460±10% |
声压级 Sound Pressure Level | dB(A) | 80±5% |
最大风量 Max. Air Flow | CFM / m3/H | 2736.525/4650 |
最大静压 Max. Static Pressure | In.wg /Pa | 1.1/275 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP54 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FG3G350-2APL-20 is a high-capacity axial fan with an integrated safety grille, engineered for industrial ventilation where robust airflow (4650 m³/h) and operator protection are critical. Powered by a brushless EC motor (BLEC102) and featuring fiberglass-reinforced plastic blades, it combines corrosion resistance with IP54-rated dust/moisture protection. Ideal for harsh environments like factories or agricultural facilities.
Safety-First Grille Design
Integrated steel grille prevents accidental contact with blades—essential for OSHA-compliant installations in high-traffic areas. Maintains 4650 m³/h airflow without compromising safety.
Corrosion-Resistant Construction
Fiberglass-reinforced impeller withstands chemical exposure and humidity, outperforming standard plastics in agricultural/industrial settings. Aluminum housing adds structural rigidity.
Smart Industrial Connectivity
Features RS485 Modbus (via RSA/RSB wires) for centralized control and dry-contact alarms (NC/COM) to trigger safety shutdowns during faults. Includes 0–10VDC/PWM speed input and FG tachometer (5 pulses/rev).
Factory Floor Ventilation: Fume extraction in welding shops or chemical plants.
Grain Handling Systems: Dust-prone environments requiring spark-resistant components.
Wastewater Treatment: Corrosion-resistant airflow for aeration basins or pump rooms.
Q1: Can the grille be removed for cleaning?
No—it’s permanently fixed for safety. Clean externally using low-pressure air or a soft brush.
Q2: How do Modbus controls improve operations?
Use RSA (Green)/RSB (Purple) wires to daisy-chain fans, enabling speed synchronization and real-time diagnostics from a central HMI.
Q3: What triggers the alarm contacts (NC/COM)?
They close during motor overload, bearing failure, or blockage—sending signals to PLCs for automated responses.
Q4: Is this fan suitable for explosive environments?
No. For ATEX zones, request our intrinsically safe models.




Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH | |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH | |