Availability: | |
---|---|
Quantity: | |
FB3G400-2APK-60
Fanova
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 3.3±10% |
转速 Speed(RPM) | min-1 | 1700±5% |
功率消耗 Power consumption | W | 750±10% |
声压级 Sound Pressure Level | dB(A) | 83±5% |
最大风量 Max. Air Flow | CFM / m3/H | 3736.98/6350 |
最大静压 Max. Static Pressure | In.wg /Pa | 3.8/950 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP54 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FB3G400-2APK-60 is a high-capacity centrifugal fan engineered for industrial ventilation demanding extreme airflow and static pressure. Powered by a single-phase 230V AC EC motor (BLEC102), it delivers 6,350 m³/h airflow at 950 Pa static pressure—ideal for large-scale exhaust systems. Its IP54-rated construction integrates smart monitoring via RS485 (MODBUS) and alarm contacts for critical environment applications.
Industrial-Grade Airflow Capacity
400mm glass-fiber-reinforced impeller generates massive 6,350 m³/h airflow for warehouses, factories, or smokestack exhaust systems.
Smart Monitoring & Alerts
RS485 (MODBUS) enables real-time control via PLCs. Dedicated alarm contacts (NC/COM) trigger warnings for thermal/fault events.
Single-Phase AC Simplicity
Operates on standard 230V AC (184–270V range), eliminating complex power conversions while supporting soft-start protection.
Industrial Exhaust: Foundries, chemical plants, welding fume extraction.
Large Commercial HVAC: Shopping malls, airport ventilation, data center cooling.
Energy Recovery Systems: High-volume ERUs, heat reclaim for industrial processes.
Q1: Can this fan replace three-phase units in existing systems?
A: Yes—its single-phase 230V AC design simplifies retrofits without sacrificing performance vs. three-phase alternatives.
Q2: How are alarm contacts (NC/COM) utilized?
A: Connect to PLCs or warning lights; contacts open during faults (overheat, lock-rotor) for immediate intervention.
Q3: Does the plastic impeller handle high temperatures?
A: Glass-fiber reinforcement ensures stability up to 85°C—avoid direct exposure to flames/chemicals.
Q4: Is MODBUS control compatible with legacy systems?
A: Yes—use RSA (A+)/RSB (B-) wires for seamless integration with industrial automation protocols.
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 3.3±10% |
转速 Speed(RPM) | min-1 | 1700±5% |
功率消耗 Power consumption | W | 750±10% |
声压级 Sound Pressure Level | dB(A) | 83±5% |
最大风量 Max. Air Flow | CFM / m3/H | 3736.98/6350 |
最大静压 Max. Static Pressure | In.wg /Pa | 3.8/950 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP54 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FB3G400-2APK-60 is a high-capacity centrifugal fan engineered for industrial ventilation demanding extreme airflow and static pressure. Powered by a single-phase 230V AC EC motor (BLEC102), it delivers 6,350 m³/h airflow at 950 Pa static pressure—ideal for large-scale exhaust systems. Its IP54-rated construction integrates smart monitoring via RS485 (MODBUS) and alarm contacts for critical environment applications.
Industrial-Grade Airflow Capacity
400mm glass-fiber-reinforced impeller generates massive 6,350 m³/h airflow for warehouses, factories, or smokestack exhaust systems.
Smart Monitoring & Alerts
RS485 (MODBUS) enables real-time control via PLCs. Dedicated alarm contacts (NC/COM) trigger warnings for thermal/fault events.
Single-Phase AC Simplicity
Operates on standard 230V AC (184–270V range), eliminating complex power conversions while supporting soft-start protection.
Industrial Exhaust: Foundries, chemical plants, welding fume extraction.
Large Commercial HVAC: Shopping malls, airport ventilation, data center cooling.
Energy Recovery Systems: High-volume ERUs, heat reclaim for industrial processes.
Q1: Can this fan replace three-phase units in existing systems?
A: Yes—its single-phase 230V AC design simplifies retrofits without sacrificing performance vs. three-phase alternatives.
Q2: How are alarm contacts (NC/COM) utilized?
A: Connect to PLCs or warning lights; contacts open during faults (overheat, lock-rotor) for immediate intervention.
Q3: Does the plastic impeller handle high temperatures?
A: Glass-fiber reinforcement ensures stability up to 85°C—avoid direct exposure to flames/chemicals.
Q4: Is MODBUS control compatible with legacy systems?
A: Yes—use RSA (A+)/RSB (B-) wires for seamless integration with industrial automation protocols.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |