Availability: | |
---|---|
Quantity: | |
FB3G400-4AAL-30
Fanova
相 Phase | ~ | 3~ |
额定电压 Nominal Voltage | VAC | 380 |
电压范围 Nominal voltage range | VAC | 304V~456V |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 2.9±10% |
转速 Speed(RPM) | min-1 | 2250±5% |
功率消耗 Power consumption | W | 1700±10% |
声压级 Sound Pressure Level | dB(A) | 87±5% |
最大风量 Max. Air Flow | CFM / m3/H | 4443.18/7550 |
最大静压 Max. Static Pressure | In.wg /Pa | 3.72/930 |
绝缘等级 Insulation class | ~ | Class F |
防护等级 Degree of protection | ~ | IP54 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FB3G400-4AAL-30 is a high-capacity EC backward centrifugal fan engineered for heavy-duty industrial ventilation. Powered by a robust EC motor (BLEC137) and featuring an 8-blade aluminum impeller (400mm diameter), it delivers extreme airflow (7550 m³/H) at 380VAC while maintaining precision control via dual-mode inputs (0–10VDC/PWM or RS485 Modbus). Designed for continuous operation (S1 duty) with IP54 protection and compliance with CE, RoHS, and ErP 2015 standards.
Industrial-Grade Airflow Performance
Generates 7550 m³/H airflow and 930 Pa static pressure—ideal for large-scale HVAC systems or factory exhaust—while operating efficiently at 1700W (±10%).
Advanced Control Integration
Supports flexible speed modulation via 0–10VDC/PWM or RS485 Modbus (RSA/RSB), with real-time RPM feedback (FG: 5 pulses/revolution) for automated systems.
Heavy-Duty Resilience
Withstands harsh environments (–25°C to 60°C) using die-cast aluminum construction, IP54-rated sealing, and multi-protection safeguards (overvoltage/locked-rotor/thermal overload).
Industrial Ventilation: High-volume air exchange in foundries, welding shops, or chemical plants.
Commercial HVAC: Central air handling units (AHUs) and ducted exhaust systems.
Power Infrastructure: Cooling for transformers, turbine enclosures, or generator rooms.
Process Automation: Integration into smart manufacturing lines via Modbus communication.
Q: Can it operate with unstable grid voltage?
A: Yes—wide voltage tolerance (304–456VAC) ensures stable performance during fluctuations.
Q: How is the RS485 interface used?
A: Connect RSA (Green) and RSB (Purple) wires for Modbus-enabled speed control or system diagnostics.
Q: What safety certifications apply?
A: Complies with EN 60204-1 (electrical safety), ISO 12100 (mechanical safety), and harmonic/EMC standards (EN 61000-3-2/3-3).
Q: Is the +10VDC output externally powered?
A: No—it’s an internal reference voltage (max. 1.1mA) for control signals or FG pull-up.
相 Phase | ~ | 3~ |
额定电压 Nominal Voltage | VAC | 380 |
电压范围 Nominal voltage range | VAC | 304V~456V |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 2.9±10% |
转速 Speed(RPM) | min-1 | 2250±5% |
功率消耗 Power consumption | W | 1700±10% |
声压级 Sound Pressure Level | dB(A) | 87±5% |
最大风量 Max. Air Flow | CFM / m3/H | 4443.18/7550 |
最大静压 Max. Static Pressure | In.wg /Pa | 3.72/930 |
绝缘等级 Insulation class | ~ | Class F |
防护等级 Degree of protection | ~ | IP54 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FB3G400-4AAL-30 is a high-capacity EC backward centrifugal fan engineered for heavy-duty industrial ventilation. Powered by a robust EC motor (BLEC137) and featuring an 8-blade aluminum impeller (400mm diameter), it delivers extreme airflow (7550 m³/H) at 380VAC while maintaining precision control via dual-mode inputs (0–10VDC/PWM or RS485 Modbus). Designed for continuous operation (S1 duty) with IP54 protection and compliance with CE, RoHS, and ErP 2015 standards.
Industrial-Grade Airflow Performance
Generates 7550 m³/H airflow and 930 Pa static pressure—ideal for large-scale HVAC systems or factory exhaust—while operating efficiently at 1700W (±10%).
Advanced Control Integration
Supports flexible speed modulation via 0–10VDC/PWM or RS485 Modbus (RSA/RSB), with real-time RPM feedback (FG: 5 pulses/revolution) for automated systems.
Heavy-Duty Resilience
Withstands harsh environments (–25°C to 60°C) using die-cast aluminum construction, IP54-rated sealing, and multi-protection safeguards (overvoltage/locked-rotor/thermal overload).
Industrial Ventilation: High-volume air exchange in foundries, welding shops, or chemical plants.
Commercial HVAC: Central air handling units (AHUs) and ducted exhaust systems.
Power Infrastructure: Cooling for transformers, turbine enclosures, or generator rooms.
Process Automation: Integration into smart manufacturing lines via Modbus communication.
Q: Can it operate with unstable grid voltage?
A: Yes—wide voltage tolerance (304–456VAC) ensures stable performance during fluctuations.
Q: How is the RS485 interface used?
A: Connect RSA (Green) and RSB (Purple) wires for Modbus-enabled speed control or system diagnostics.
Q: What safety certifications apply?
A: Complies with EN 60204-1 (electrical safety), ISO 12100 (mechanical safety), and harmonic/EMC standards (EN 61000-3-2/3-3).
Q: Is the +10VDC output externally powered?
A: No—it’s an internal reference voltage (max. 1.1mA) for control signals or FG pull-up.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |