Availability: | |
---|---|
Quantity: | |
FB3G450-2AAL-20
Fanova
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 2.1±10% |
转速 Speed(RPM) | min-1 | 1300±5% |
功率消耗 Power consumption | W | 500±10% |
声压级 Sound Pressure Level | dB(A) | 76±5% |
最大风量 Max. Air Flow | CFM / m3/H | 3595.74/6110 |
最大静压 Max. Static Pressure | In.wg /Pa | 1.82/455 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP54 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FB3G450-2AAL-20 is a heavy-duty backward centrifugal fan engineered by Fanova (Suzhou) for industrial-scale ventilation requiring massive airflow. Powered by a high-efficiency EC motor (BLEC102), it delivers exceptional air movement at lower noise levels while operating on 230V AC systems. Designed for continuous operation in demanding environments, it features IP54 protection, advanced control interfaces, and complies with CE, RoHS, and ErP2015 standards.
Industrial-Grade Airflow Capacity
Generates 6,110 m³/h max airflow—equivalent to small wind tunnels—with 455 Pa static pressure at 1,300 RPM. The 450mm aluminum impeller (6 blades) ensures robust performance for large-space ventilation.
Energy-Efficient EC Motor
Reduces power consumption (500W max) versus traditional AC fans while maintaining wide voltage compatibility (184–270V AC). Soft-start protection minimizes inrush current.
Smart Control & Monitoring
Supports 0–10VDC/PWM speed control, RS485/MODBUS communication, and alarm switches (NC/COM) for real-time fault alerts. The +10VDC output powers FG tachometers (5 pulses/revolution).
Heavy-Duty Construction
Die-cast aluminum housing and impeller resist corrosion. IP54-rated against dust/water ingress and operates reliably from –25°C to 60°C with 50,000-hour lifespan (L10).
Warehouse Ventilation: High-volume air exchange in logistics centers or manufacturing plants.
Industrial Process Cooling: Heat extraction for furnaces, ovens, or production lines.
Large HVAC Systems: Air handling units (AHUs) in commercial complexes or data centers.
Q1: Can MODBUS communication integrate with existing SCADA systems?
A1: Yes. The RSA/RSB terminals enable seamless integration for centralized monitoring and control.
Q2: What triggers the alarm switch (NC/COM)?
A2: Thermal overloads, locked rotors, or voltage faults activate the dry-contact output for safety shutdowns or alerts.
Q3: How does this fan reduce energy costs versus traditional blowers?
A3: The EC motor adjusts speed precisely to demand, cutting power use by 30–50% versus fixed-speed AC units.
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 2.1±10% |
转速 Speed(RPM) | min-1 | 1300±5% |
功率消耗 Power consumption | W | 500±10% |
声压级 Sound Pressure Level | dB(A) | 76±5% |
最大风量 Max. Air Flow | CFM / m3/H | 3595.74/6110 |
最大静压 Max. Static Pressure | In.wg /Pa | 1.82/455 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP54 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FB3G450-2AAL-20 is a heavy-duty backward centrifugal fan engineered by Fanova (Suzhou) for industrial-scale ventilation requiring massive airflow. Powered by a high-efficiency EC motor (BLEC102), it delivers exceptional air movement at lower noise levels while operating on 230V AC systems. Designed for continuous operation in demanding environments, it features IP54 protection, advanced control interfaces, and complies with CE, RoHS, and ErP2015 standards.
Industrial-Grade Airflow Capacity
Generates 6,110 m³/h max airflow—equivalent to small wind tunnels—with 455 Pa static pressure at 1,300 RPM. The 450mm aluminum impeller (6 blades) ensures robust performance for large-space ventilation.
Energy-Efficient EC Motor
Reduces power consumption (500W max) versus traditional AC fans while maintaining wide voltage compatibility (184–270V AC). Soft-start protection minimizes inrush current.
Smart Control & Monitoring
Supports 0–10VDC/PWM speed control, RS485/MODBUS communication, and alarm switches (NC/COM) for real-time fault alerts. The +10VDC output powers FG tachometers (5 pulses/revolution).
Heavy-Duty Construction
Die-cast aluminum housing and impeller resist corrosion. IP54-rated against dust/water ingress and operates reliably from –25°C to 60°C with 50,000-hour lifespan (L10).
Warehouse Ventilation: High-volume air exchange in logistics centers or manufacturing plants.
Industrial Process Cooling: Heat extraction for furnaces, ovens, or production lines.
Large HVAC Systems: Air handling units (AHUs) in commercial complexes or data centers.
Q1: Can MODBUS communication integrate with existing SCADA systems?
A1: Yes. The RSA/RSB terminals enable seamless integration for centralized monitoring and control.
Q2: What triggers the alarm switch (NC/COM)?
A2: Thermal overloads, locked rotors, or voltage faults activate the dry-contact output for safety shutdowns or alerts.
Q3: How does this fan reduce energy costs versus traditional blowers?
A3: The EC motor adjusts speed precisely to demand, cutting power use by 30–50% versus fixed-speed AC units.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |