Availability: | |
---|---|
Quantity: | |
FD3G133-24GL-91
Fanova
Nominal Voltage | VDC | 24 |
Nominal voltage range | VDC | 16~28 |
Current draw | A | 6.0±10% |
Speed(RPM) | min-1 | 1780±5% |
Power consumption | W | 144±10% |
Sound Pressure Level | dB(A) | 68±5% |
Max. Air Flow | CFM / m3/H | 447.26/760 |
Max. Static Pressure | In.wg /Pa | 2.0/500 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
The FD3G133-24GL-91 is a compact dual-inlet DC centrifugal fan engineered for precision cooling in space-constrained industrial systems. Featuring a 133mm galvanized steel impeller and a 24VDC BLDC motor (Model BLDC72), it delivers high static pressure (500 Pa) with moderate airflow (760 m³/h) while operating at low noise levels (68 dB(A)). Designed for IP44 protection and wide voltage input (16–28VDC), it excels in applications demanding reliability, quiet operation, and resistance to harsh conditions.
High Pressure in Compact Design
Generates 500 Pa static pressure within a 133mm footprint—ideal for overcoming resistance in tight enclosures or dense filter systems without compromising space efficiency.
Robust Metal Construction
38-blade galvanized steel impeller ensures corrosion resistance and mechanical stability for demanding environments (-25°C to 60°C), extending operational lifespan.
Low-Noise Efficiency
Operates at 68 dB(A) despite high blade count—optimized aerodynamics reduce turbulence at 1,780 RPM for quiet performance in sensitive settings.
Plug-and-Play Integration
Simplified wiring (24VDC input, PWM control, 2-pulse FG tachometer) with soft-start and reverse-polarity protection enables quick installation.
Medical Devices: Cooling for diagnostic imaging equipment (e.g., MRI, CT scanners).
Laboratory Instruments: Ventilation in spectrometers, chromatographs, or precision scales.
Industrial Control Cabinets: Thermal management in PLC enclosures or servo drives.
Audio/Visual Racks: Silent cooling for broadcast or recording studio gear.
Q: Why choose galvanized steel over plastic impellers?
A: Steel resists wear in high-stress/pressure scenarios and maintains integrity under thermal cycling—critical for 500 Pa output.
Q: Can the 2-pulse FG signal synchronize with controllers?
A: Yes—provides real-time RPM feedback (2 pulses/revolution) for system monitoring or speed synchronization.
Q: Is it suitable for dusty environments?
A: IP44 rating protects against particulate ingress; pair with filters for extended longevity in abrasive conditions.
Nominal Voltage | VDC | 24 |
Nominal voltage range | VDC | 16~28 |
Current draw | A | 6.0±10% |
Speed(RPM) | min-1 | 1780±5% |
Power consumption | W | 144±10% |
Sound Pressure Level | dB(A) | 68±5% |
Max. Air Flow | CFM / m3/H | 447.26/760 |
Max. Static Pressure | In.wg /Pa | 2.0/500 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
The FD3G133-24GL-91 is a compact dual-inlet DC centrifugal fan engineered for precision cooling in space-constrained industrial systems. Featuring a 133mm galvanized steel impeller and a 24VDC BLDC motor (Model BLDC72), it delivers high static pressure (500 Pa) with moderate airflow (760 m³/h) while operating at low noise levels (68 dB(A)). Designed for IP44 protection and wide voltage input (16–28VDC), it excels in applications demanding reliability, quiet operation, and resistance to harsh conditions.
High Pressure in Compact Design
Generates 500 Pa static pressure within a 133mm footprint—ideal for overcoming resistance in tight enclosures or dense filter systems without compromising space efficiency.
Robust Metal Construction
38-blade galvanized steel impeller ensures corrosion resistance and mechanical stability for demanding environments (-25°C to 60°C), extending operational lifespan.
Low-Noise Efficiency
Operates at 68 dB(A) despite high blade count—optimized aerodynamics reduce turbulence at 1,780 RPM for quiet performance in sensitive settings.
Plug-and-Play Integration
Simplified wiring (24VDC input, PWM control, 2-pulse FG tachometer) with soft-start and reverse-polarity protection enables quick installation.
Medical Devices: Cooling for diagnostic imaging equipment (e.g., MRI, CT scanners).
Laboratory Instruments: Ventilation in spectrometers, chromatographs, or precision scales.
Industrial Control Cabinets: Thermal management in PLC enclosures or servo drives.
Audio/Visual Racks: Silent cooling for broadcast or recording studio gear.
Q: Why choose galvanized steel over plastic impellers?
A: Steel resists wear in high-stress/pressure scenarios and maintains integrity under thermal cycling—critical for 500 Pa output.
Q: Can the 2-pulse FG signal synchronize with controllers?
A: Yes—provides real-time RPM feedback (2 pulses/revolution) for system monitoring or speed synchronization.
Q: Is it suitable for dusty environments?
A: IP44 rating protects against particulate ingress; pair with filters for extended longevity in abrasive conditions.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |