Availability: | |
---|---|
Quantity: | |
FK3G225-48PY-70
Fanova
Nominal Voltage | VDC | 48 |
Nominal voltage range | VDC | 36~57 |
Current draw | A | 2.4±10% |
Speed(RPM) | min-1 | 2300±5% |
Power consumption | W | 115±10% |
Sound Pressure Level | dB(A) | 67±5% |
Max. Air Flow | CFM / m3/H | 632.05/1074 |
Max. Static Pressure | In.wg /Pa | 1.648/412 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
Product Overview
The 48V-DC 225mm 115W External-Rotor Centrifugal Blower Fan with Support Bracket integrates the motor and impeller into a compact external-rotor unit. Designed for efficient airflow in space-conscious applications, it delivers reliable performance for systems requiring moderate static pressure (412 Pa max), such as compact ductwork or filtration setups.
Features
External-Rotor Motor Design
The stator-fixed design enables the rotor to drive the impeller directly, eliminating belts or gears. This integration reduces energy loss and mechanical complexity.
Moderate Static Pressure Performance
Generates 412 Pa maximum static pressure, suitable for overcoming resistance in shorter ducts or standard filters. Maintains airflow consistency up to 1,074 m³/h.
Low Noise Operation
Aerodynamically tuned blades operate at 67 dB(A) under full load, ideal for environments where noise reduction is prioritized.
Wide Voltage Range
Compatible with 36-57V DC power supplies, ensuring stable operation in off-grid or mobile systems with voltage fluctuations.
Applications
Compact HVAC Systems: Air handling in small commercial units or server racks.
Light Industrial Ventilation: Cooling for control cabinets, machinery enclosures, or localized exhaust.
Filtration Units: Pushing air through standard filters in purifiers or light-duty cleanrooms.
Mobile Platforms: Integration into vehicles or portable equipment with limited space.
Nominal Voltage | VDC | 48 |
Nominal voltage range | VDC | 36~57 |
Current draw | A | 2.4±10% |
Speed(RPM) | min-1 | 2300±5% |
Power consumption | W | 115±10% |
Sound Pressure Level | dB(A) | 67±5% |
Max. Air Flow | CFM / m3/H | 632.05/1074 |
Max. Static Pressure | In.wg /Pa | 1.648/412 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
Product Overview
The 48V-DC 225mm 115W External-Rotor Centrifugal Blower Fan with Support Bracket integrates the motor and impeller into a compact external-rotor unit. Designed for efficient airflow in space-conscious applications, it delivers reliable performance for systems requiring moderate static pressure (412 Pa max), such as compact ductwork or filtration setups.
Features
External-Rotor Motor Design
The stator-fixed design enables the rotor to drive the impeller directly, eliminating belts or gears. This integration reduces energy loss and mechanical complexity.
Moderate Static Pressure Performance
Generates 412 Pa maximum static pressure, suitable for overcoming resistance in shorter ducts or standard filters. Maintains airflow consistency up to 1,074 m³/h.
Low Noise Operation
Aerodynamically tuned blades operate at 67 dB(A) under full load, ideal for environments where noise reduction is prioritized.
Wide Voltage Range
Compatible with 36-57V DC power supplies, ensuring stable operation in off-grid or mobile systems with voltage fluctuations.
Applications
Compact HVAC Systems: Air handling in small commercial units or server racks.
Light Industrial Ventilation: Cooling for control cabinets, machinery enclosures, or localized exhaust.
Filtration Units: Pushing air through standard filters in purifiers or light-duty cleanrooms.
Mobile Platforms: Integration into vehicles or portable equipment with limited space.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |