Nominal Voltage | VDC | 110 |
Nominal voltage range | VDC | 36~57 |
Current draw | A | 3.9±10% |
Speed(RPM) | min-1 | 1600±5% |
Power consumption | W | 420±10% |
Sound Pressure Level | dB(A) | 68±5% |
Max. Air Flow | CFM / m3/H | 3619.28/6150 |
Max. Static Pressure | In.wg /Pa | 1.0/250 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
The FG3G450-110PL-20 is a high-voltage DC axial fan with integrated safety grille, engineered for industrial ventilation where operator protection is critical. Combining a 450mm glass-fiber-reinforced impeller and robust BLDC102 motor, it delivers efficient airflow (6,150 m³/h) at 110VDC while ensuring operational safety in high-traffic environments. Certified to CE/RoHS/ErP standards, it thrives in demanding settings from manufacturing plants to heavy equipment cooling.
Safety-First Design with Guard Grille
Features a built-in protective grille to prevent accidental contact with rotating blades, ideal for accessible installations. IP44-rated housing resists dust and water splashes, enhancing durability in harsh conditions.
High-Voltage DC Efficiency
Optimized for 110VDC systems (88–132VDC range), delivering 6150 m³/h (3,619 CFM) airflow at 250 Pa static pressure with low noise (68 dB(A)). Energy-efficient EC technology reduces power consumption (420W ±10%) versus traditional AC fans.
Simplified Integration
Supports universal mounting (any orientation) and plug-and-play wiring with color-coded cables. Includes tachometer output (FG signal: 3 pulses/revolution) for real-time RPM monitoring and 0–10VDC/PWM speed control.
Industrial machinery cooling (CNC equipment, compressors)
HVAC exhaust systems in factories/warehouses
Safety-critical ventilation (conveyor belts, assembly lines)
Renewable energy installations (solar inverters, battery cabinets)
Q1: Can the guard grille be removed for cleaning?
A1: No—the grille is permanently fixed to ensure continuous safety compliance. Clean externally with low-pressure air.
Q2: Is this fan compatible with AC power supplies?
A2: No, it requires a 110VDC power source. Use with AC will damage the motor.
Q3: What makes DC fans preferable to AC in industrial settings?
A3: DC fans offer precise speed control, higher efficiency at partial loads, and lower electromagnetic interference (EMI).
Q4: How is the FG signal utilized?
A4: Connect the white wire to controllers for real-time fault detection (e.g., stall alerts) or airflow verification.
Nominal Voltage | VDC | 110 |
Nominal voltage range | VDC | 36~57 |
Current draw | A | 3.9±10% |
Speed(RPM) | min-1 | 1600±5% |
Power consumption | W | 420±10% |
Sound Pressure Level | dB(A) | 68±5% |
Max. Air Flow | CFM / m3/H | 3619.28/6150 |
Max. Static Pressure | In.wg /Pa | 1.0/250 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
The FG3G450-110PL-20 is a high-voltage DC axial fan with integrated safety grille, engineered for industrial ventilation where operator protection is critical. Combining a 450mm glass-fiber-reinforced impeller and robust BLDC102 motor, it delivers efficient airflow (6,150 m³/h) at 110VDC while ensuring operational safety in high-traffic environments. Certified to CE/RoHS/ErP standards, it thrives in demanding settings from manufacturing plants to heavy equipment cooling.
Safety-First Design with Guard Grille
Features a built-in protective grille to prevent accidental contact with rotating blades, ideal for accessible installations. IP44-rated housing resists dust and water splashes, enhancing durability in harsh conditions.
High-Voltage DC Efficiency
Optimized for 110VDC systems (88–132VDC range), delivering 6150 m³/h (3,619 CFM) airflow at 250 Pa static pressure with low noise (68 dB(A)). Energy-efficient EC technology reduces power consumption (420W ±10%) versus traditional AC fans.
Simplified Integration
Supports universal mounting (any orientation) and plug-and-play wiring with color-coded cables. Includes tachometer output (FG signal: 3 pulses/revolution) for real-time RPM monitoring and 0–10VDC/PWM speed control.
Industrial machinery cooling (CNC equipment, compressors)
HVAC exhaust systems in factories/warehouses
Safety-critical ventilation (conveyor belts, assembly lines)
Renewable energy installations (solar inverters, battery cabinets)
Q1: Can the guard grille be removed for cleaning?
A1: No—the grille is permanently fixed to ensure continuous safety compliance. Clean externally with low-pressure air.
Q2: Is this fan compatible with AC power supplies?
A2: No, it requires a 110VDC power source. Use with AC will damage the motor.
Q3: What makes DC fans preferable to AC in industrial settings?
A3: DC fans offer precise speed control, higher efficiency at partial loads, and lower electromagnetic interference (EMI).
Q4: How is the FG signal utilized?
A4: Connect the white wire to controllers for real-time fault detection (e.g., stall alerts) or airflow verification.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |