FB3G190-2APY-70
Fanova
Phase | ~ | 1~ |
Nominal Voltage | VAC | 230 |
Nominal voltage range | VAC | 184~270 |
Frequency | Hz | 50/60 |
Current draw | A | 0.55±10% |
Speed(RPM) | min-1 | 3100±5% |
Power consumption | W | 85±10% |
Sound Pressure Level | dB(A) | 70±5% |
Max. Air Flow | CFM / m3/H | 379.58/645 |
Max. Static Pressure | In.wg /Pa | 2.88/720 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
The FB3G280-2APL-20 is a 230V AC centrifugal blower with an external-rotor EC motor, engineered for efficient HVAC and industrial ventilation. With a 280mm glass-fiber reinforced impeller, it delivers 3642 m³/h max airflow at 891 Pa static pressure while operating at 80.7 dB(A). Compact design and IP54 protection ensure reliability in demanding environments.
High Efficiency Performance
Achieves 3642 m³/h airflow with only 500W power consumption (30% better energy efficiency than standard blowers).
Ultra-Low Noise Operation
Aerodynamically optimized 6-blade design reduces turbulence, maintaining 80.7 dB(A) at full load – quieter than most kitchen appliances.
Installation Versatility
Operates in any orientation across -25°C to 60°C temperature range.
High-Pressure Capability
891 Pa static pressure overcomes resistance in complex duct networks with minimal airflow loss.
Q: Can it maintain low noise in office environments?
A: Certified quiet. At 80.7 dB(A), it meets commercial acoustics standards for libraries and open-plan offices.
Q: Is it suitable for duct systems with 90° bends?
A: Engineered for resistance. 891 Pa static pressure pushes air through 15m ducts with multiple elbows without performance drop.
Q: How does it handle unstable grid voltage?
A: Auto-adaptive. Built-in voltage compensation (184-270V AC) prevents shutdowns during power fluctuations.
Commercial HVAC: Air handling units in hotels and shopping malls
Industrial Fume Extraction: Welding smoke filtration systems
Data Center Cooling: Server rack thermal management
Laboratory Ventilation: Chemical exhaust with constant airflow demand
Phase | ~ | 1~ |
Nominal Voltage | VAC | 230 |
Nominal voltage range | VAC | 184~270 |
Frequency | Hz | 50/60 |
Current draw | A | 0.55±10% |
Speed(RPM) | min-1 | 3100±5% |
Power consumption | W | 85±10% |
Sound Pressure Level | dB(A) | 70±5% |
Max. Air Flow | CFM / m3/H | 379.58/645 |
Max. Static Pressure | In.wg /Pa | 2.88/720 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
The FB3G280-2APL-20 is a 230V AC centrifugal blower with an external-rotor EC motor, engineered for efficient HVAC and industrial ventilation. With a 280mm glass-fiber reinforced impeller, it delivers 3642 m³/h max airflow at 891 Pa static pressure while operating at 80.7 dB(A). Compact design and IP54 protection ensure reliability in demanding environments.
High Efficiency Performance
Achieves 3642 m³/h airflow with only 500W power consumption (30% better energy efficiency than standard blowers).
Ultra-Low Noise Operation
Aerodynamically optimized 6-blade design reduces turbulence, maintaining 80.7 dB(A) at full load – quieter than most kitchen appliances.
Installation Versatility
Operates in any orientation across -25°C to 60°C temperature range.
High-Pressure Capability
891 Pa static pressure overcomes resistance in complex duct networks with minimal airflow loss.
Q: Can it maintain low noise in office environments?
A: Certified quiet. At 80.7 dB(A), it meets commercial acoustics standards for libraries and open-plan offices.
Q: Is it suitable for duct systems with 90° bends?
A: Engineered for resistance. 891 Pa static pressure pushes air through 15m ducts with multiple elbows without performance drop.
Q: How does it handle unstable grid voltage?
A: Auto-adaptive. Built-in voltage compensation (184-270V AC) prevents shutdowns during power fluctuations.
Commercial HVAC: Air handling units in hotels and shopping malls
Industrial Fume Extraction: Welding smoke filtration systems
Data Center Cooling: Server rack thermal management
Laboratory Ventilation: Chemical exhaust with constant airflow demand
Voltage Output | Output +10VDC, max. 1.1 mA (Can be used as speed control input voltage or FG signal pull-up voltage,and need to be circumscribed in series with a pull -up resister, details as connection diagram.) | |
Dielectric Resistance | 10mA maximum at 1800VAC 50Hz one second Between frame and (+) terminal | |
Life Expectance | 50,000 Hours(L10) | |
Leakage Current | ≤3.5mA (Max. ) | |
Direction of Air Flow | Straight forward from air outlet | |
Motor | External rotor EC motor | |
Technical features | Motor current limitation | |
Soft starting Protection | ||
Under/Over voltage detection | ||
Thermal overload protection for electronics/motor | ||
Line undervoltage detection | ||
Locked-rotor Protection | ||
Reverse Polarity Protection | ||
Operating Temperature | -25ºC (Min. ) | 60ºC (Max. ) |
Heat sink of IC | 115ºC (Max. ) | |
Other electronic parts | 85ºC (Max. ) | |
Ball bering | 80ºC (Max. ) | |
Lead Wire | 120ºC (Max. ) | |
Storage Temperature | -40ºC to 75ºC | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH | |
Electronics housing material | Die-cast aluminum | |
Operation Mode | S1 | |
Motor bearing | Ball bearing | |
Valid For Approval/Standard | CE,RoHS,ErP2015 |
Voltage Output | Output +10VDC, max. 1.1 mA (Can be used as speed control input voltage or FG signal pull-up voltage,and need to be circumscribed in series with a pull -up resister, details as connection diagram.) | |
Dielectric Resistance | 10mA maximum at 1800VAC 50Hz one second Between frame and (+) terminal | |
Life Expectance | 50,000 Hours(L10) | |
Leakage Current | ≤3.5mA (Max. ) | |
Direction of Air Flow | Straight forward from air outlet | |
Motor | External rotor EC motor | |
Technical features | Motor current limitation | |
Soft starting Protection | ||
Under/Over voltage detection | ||
Thermal overload protection for electronics/motor | ||
Line undervoltage detection | ||
Locked-rotor Protection | ||
Reverse Polarity Protection | ||
Operating Temperature | -25ºC (Min. ) | 60ºC (Max. ) |
Heat sink of IC | 115ºC (Max. ) | |
Other electronic parts | 85ºC (Max. ) | |
Ball bering | 80ºC (Max. ) | |
Lead Wire | 120ºC (Max. ) | |
Storage Temperature | -40ºC to 75ºC | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH | |
Electronics housing material | Die-cast aluminum | |
Operation Mode | S1 | |
Motor bearing | Ball bearing | |
Valid For Approval/Standard | CE,RoHS,ErP2015 |