Availability: | |
---|---|
Quantity: | |
FD3G146-2AGL-90外置电控板
Fanova
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 2.2±10% |
转速 Speed(RPM) | min-1 | 1850±5% |
功率消耗 Power consumption | W | 260±10% |
声压级 Sound Pressure Level | dB(A) | 74±5% |
最大风量 Max. Air Flow | CFM / m3/H | 882.1615/1499 |
最大静压 Max. Static Pressure | In.wg /Pa | 2.16/540 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP44 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
230V AC Dual-Inlet Centrifugal Fan (146mm impeller, 190W) delivers 1,200 m³/h airflow at 425 Pa static pressure through its symmetrical dual-intake design. Equipped with an EC motor (BLEC92) and wide voltage input (184–270V AC), it ensures stable operation in space-constrained precision cooling applications.
Balanced Air Entrainment: Dual inlets reduce turbulence by 15% vs. single-inlet designs, enhancing volumetric efficiency.
38 Galvanized Steel Blades: Forward-curved aerodynamics achieve 72.1 dB(A) noise – ideal for noise-sensitive environments.
0–10V/PWM Speed Control: Seamless 30–100% RPM adjustment via external signals.
Voltage Resilience: Maintains < ±3.5% speed deviation under 184–270V AC fluctuations.
Real-Time Monitoring: FG output (4 pulses/rev) enables live RPM tracking.
Corrosion-Resistant Impeller: Zinc-coated steel withstands humid/chemical environments (e.g., medical disinfection).
IP54 Protection: Blocks dust (≥1mm particles) and water splashes.
-25°C to 60°C Operating Range: Ball bearings ensure performance in extreme conditions.
Soft-Start Circuit: Prevents inrush current damage.
Over/Under Voltage Cutoff: Automatic shutdown beyond voltage limits.
Dual Thermal Protection: Independent sensors for electronics and motor windings.
Medical Devices: Cooling for PCR machines, blood analyzers, and imaging equipment.
Telecom Infrastructure: Ventilation in 5G micro-base stations and edge servers.
Portable Purification Units: Core fan for mobile air scrubbers/disinfection systems.
Laboratory Ventilation: Biosafety cabinets and fume hood exhaust systems.
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 2.2±10% |
转速 Speed(RPM) | min-1 | 1850±5% |
功率消耗 Power consumption | W | 260±10% |
声压级 Sound Pressure Level | dB(A) | 74±5% |
最大风量 Max. Air Flow | CFM / m3/H | 882.1615/1499 |
最大静压 Max. Static Pressure | In.wg /Pa | 2.16/540 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP44 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
230V AC Dual-Inlet Centrifugal Fan (146mm impeller, 190W) delivers 1,200 m³/h airflow at 425 Pa static pressure through its symmetrical dual-intake design. Equipped with an EC motor (BLEC92) and wide voltage input (184–270V AC), it ensures stable operation in space-constrained precision cooling applications.
Balanced Air Entrainment: Dual inlets reduce turbulence by 15% vs. single-inlet designs, enhancing volumetric efficiency.
38 Galvanized Steel Blades: Forward-curved aerodynamics achieve 72.1 dB(A) noise – ideal for noise-sensitive environments.
0–10V/PWM Speed Control: Seamless 30–100% RPM adjustment via external signals.
Voltage Resilience: Maintains < ±3.5% speed deviation under 184–270V AC fluctuations.
Real-Time Monitoring: FG output (4 pulses/rev) enables live RPM tracking.
Corrosion-Resistant Impeller: Zinc-coated steel withstands humid/chemical environments (e.g., medical disinfection).
IP54 Protection: Blocks dust (≥1mm particles) and water splashes.
-25°C to 60°C Operating Range: Ball bearings ensure performance in extreme conditions.
Soft-Start Circuit: Prevents inrush current damage.
Over/Under Voltage Cutoff: Automatic shutdown beyond voltage limits.
Dual Thermal Protection: Independent sensors for electronics and motor windings.
Medical Devices: Cooling for PCR machines, blood analyzers, and imaging equipment.
Telecom Infrastructure: Ventilation in 5G micro-base stations and edge servers.
Portable Purification Units: Core fan for mobile air scrubbers/disinfection systems.
Laboratory Ventilation: Biosafety cabinets and fume hood exhaust systems.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |