Availability: | |
---|---|
Quantity: | |
FK3G225-2APY-70
Fanova
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 0.72±10% |
转速 Speed(RPM) | min-1 | 2500±5% |
功率消耗 Power consumption | W | 120±10% |
声压级 Sound Pressure Level | dB(A) | 71±5% |
最大风量 Max. Air Flow | CFM / m3/H | 646.17/1098 |
最大静压 Max. Static Pressure | In.wg /Pa | 1.79/447 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP44 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FK3G225-2APY-70 is a compact backward centrifugal fan engineered for high-efficiency mid-pressure applications. Combining a 225mm glass-fiber-reinforced impeller with a robust BLEC72 EC motor and integrated support bracket, it delivers 447 Pa (1.79 in.wg) static pressure while maintaining minimal footprint. Ideal for space-constrained industrial systems, its IP44-rated housing and versatile mounting excel in demanding environments.
Precision Backward Blade Design
Features 7 optimized backward-curved blades for 30% higher efficiency than forward-curved equivalents, achieving 1,098 m³/h (646 CFM) airflow at just 120W ±10% power consumption.
Integrated Vibration Control
Factory-mounted steel bracket reduces vibration transmission by 40% versus bolt-on solutions, enabling direct installation on sensitive equipment without resonance issues.
Plug-and-Play Smart Control
Supports 0–10VDC/PWM speed tuning with tachometer feedback (2 pulses/revolution) for real-time diagnostics. Wide voltage tolerance (184–270VAC) ensures stability in fluctuating grids.
Packaged HVAC units (rooftop, ducted)
Industrial dehumidifiers and drying systems
Laboratory fume extractors
OEM machinery cooling (CNC enclosures, laser cutters)
Q1: Why choose backward blades for this size class?
A1: Backward blades minimize turbulence at mid-pressure ranges (200–500 Pa), reducing noise (71 dB(A)) while increasing efficiency—critical for continuous-duty systems.
Q2: Can the bracket handle vertical mounting?
A2: Yes, the reinforced bracket supports all orientations, including vertical exhausts or horizontal side-mounts.
Q3: How does EC motor benefit low-airflow applications?
A3: EC technology maintains >85% efficiency even at 30% speed, unlike AC motors that waste energy at partial loads.
Q4: Is it suitable for corrosive environments?
A4: The fiberglass-reinforced impeller resists mild chemicals, but for harsh settings (e.g., acid fumes), request optional PP-coated version.
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 0.72±10% |
转速 Speed(RPM) | min-1 | 2500±5% |
功率消耗 Power consumption | W | 120±10% |
声压级 Sound Pressure Level | dB(A) | 71±5% |
最大风量 Max. Air Flow | CFM / m3/H | 646.17/1098 |
最大静压 Max. Static Pressure | In.wg /Pa | 1.79/447 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP44 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FK3G225-2APY-70 is a compact backward centrifugal fan engineered for high-efficiency mid-pressure applications. Combining a 225mm glass-fiber-reinforced impeller with a robust BLEC72 EC motor and integrated support bracket, it delivers 447 Pa (1.79 in.wg) static pressure while maintaining minimal footprint. Ideal for space-constrained industrial systems, its IP44-rated housing and versatile mounting excel in demanding environments.
Precision Backward Blade Design
Features 7 optimized backward-curved blades for 30% higher efficiency than forward-curved equivalents, achieving 1,098 m³/h (646 CFM) airflow at just 120W ±10% power consumption.
Integrated Vibration Control
Factory-mounted steel bracket reduces vibration transmission by 40% versus bolt-on solutions, enabling direct installation on sensitive equipment without resonance issues.
Plug-and-Play Smart Control
Supports 0–10VDC/PWM speed tuning with tachometer feedback (2 pulses/revolution) for real-time diagnostics. Wide voltage tolerance (184–270VAC) ensures stability in fluctuating grids.
Packaged HVAC units (rooftop, ducted)
Industrial dehumidifiers and drying systems
Laboratory fume extractors
OEM machinery cooling (CNC enclosures, laser cutters)
Q1: Why choose backward blades for this size class?
A1: Backward blades minimize turbulence at mid-pressure ranges (200–500 Pa), reducing noise (71 dB(A)) while increasing efficiency—critical for continuous-duty systems.
Q2: Can the bracket handle vertical mounting?
A2: Yes, the reinforced bracket supports all orientations, including vertical exhausts or horizontal side-mounts.
Q3: How does EC motor benefit low-airflow applications?
A3: EC technology maintains >85% efficiency even at 30% speed, unlike AC motors that waste energy at partial loads.
Q4: Is it suitable for corrosive environments?
A4: The fiberglass-reinforced impeller resists mild chemicals, but for harsh settings (e.g., acid fumes), request optional PP-coated version.