Availability: | |
---|---|
Quantity: | |
FK3G310-2AAB-67
Fanova
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 3.1±10% |
转速 Speed(RPM) | min-1 | 2960±5% |
功率消耗 Power consumption | W | 700±10% |
声压级 Sound Pressure Level | dB(A) | 85±5% |
最大风量 Max. Air Flow | CFM / m3/H | 2354/4000 |
最大静压 Max. Static Pressure | In.wg /Pa | 4.24/1060 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP54 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
Engineered for high-pressure industrial ventilation, this 310mm backward-curved fan delivers 4000 m³/h airflow and exceptional 1060 Pa static pressure—ideal for overcoming resistance in ducted systems. Powered by a robust BLEC102 motor with an 8-blade aluminum impeller, it operates at 2960 RPM while maintaining IP54-rated dust/moisture resistance. Universal 230V input (184–270V AC) and flexible controls ensure seamless integration into demanding HVAC or process applications.
High-Pressure Performance
Generates 1060 Pa max static pressure—critical for long ducts, filter systems, or industrial exhausts requiring forceful air movement.
Optimized Airflow Efficiency
Aluminum impeller and balanced design achieve 4000 m³/h airflow at 700W power consumption, reducing operational costs in continuous-use scenarios.
Industrial-Grade Resilience
Die-cast aluminum housing withstands harsh environments (-25°C to 60°C), while ball bearings ensure 50,000-hour L10 lifespan.
Smart Integration Ready
Supports 0–10VDC/PWM speed control + RS485 (MODBUS). Includes soft-start, voltage protection, and FG tach signal (5 pulses/rev) for automation.
Industrial Dust Collection: High-pressure airflow for sawdust/metal fume extraction.
Commercial HVAC: Air handling units (AHUs) in factories or warehouses.
Process Drying/Curing: Oven ventilation requiring consistent pressure.
Cleanroom Pressurization: Maintaining positive airflow in labs or production zones.
Q1: Can it replace FK3G400 in high-pressure applications?
Yes. This model offers 20% higher static pressure than FK3G400 (1060 Pa vs. 950 Pa), better suited for restrictive systems.
Q2: Why aluminum over plastic impellers?
Aluminum handles higher RPM (2960 vs. 1700 in plastic models) without flex, maintaining efficiency in high-pressure setups.
Q3: Is 85 dB(A) too loud for indoor use?
Suitable for industrial floors. For offices, pair with acoustic ducting or choose quieter models (e.g., FB3G220 at 71 dB(A)).
Q4: How does MODBUS enhance control?
Enables real-time RPM monitoring, fault alerts (e.g., overheating), and synchronized multi-fan operation via building management systems.
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 3.1±10% |
转速 Speed(RPM) | min-1 | 2960±5% |
功率消耗 Power consumption | W | 700±10% |
声压级 Sound Pressure Level | dB(A) | 85±5% |
最大风量 Max. Air Flow | CFM / m3/H | 2354/4000 |
最大静压 Max. Static Pressure | In.wg /Pa | 4.24/1060 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP54 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
Engineered for high-pressure industrial ventilation, this 310mm backward-curved fan delivers 4000 m³/h airflow and exceptional 1060 Pa static pressure—ideal for overcoming resistance in ducted systems. Powered by a robust BLEC102 motor with an 8-blade aluminum impeller, it operates at 2960 RPM while maintaining IP54-rated dust/moisture resistance. Universal 230V input (184–270V AC) and flexible controls ensure seamless integration into demanding HVAC or process applications.
High-Pressure Performance
Generates 1060 Pa max static pressure—critical for long ducts, filter systems, or industrial exhausts requiring forceful air movement.
Optimized Airflow Efficiency
Aluminum impeller and balanced design achieve 4000 m³/h airflow at 700W power consumption, reducing operational costs in continuous-use scenarios.
Industrial-Grade Resilience
Die-cast aluminum housing withstands harsh environments (-25°C to 60°C), while ball bearings ensure 50,000-hour L10 lifespan.
Smart Integration Ready
Supports 0–10VDC/PWM speed control + RS485 (MODBUS). Includes soft-start, voltage protection, and FG tach signal (5 pulses/rev) for automation.
Industrial Dust Collection: High-pressure airflow for sawdust/metal fume extraction.
Commercial HVAC: Air handling units (AHUs) in factories or warehouses.
Process Drying/Curing: Oven ventilation requiring consistent pressure.
Cleanroom Pressurization: Maintaining positive airflow in labs or production zones.
Q1: Can it replace FK3G400 in high-pressure applications?
Yes. This model offers 20% higher static pressure than FK3G400 (1060 Pa vs. 950 Pa), better suited for restrictive systems.
Q2: Why aluminum over plastic impellers?
Aluminum handles higher RPM (2960 vs. 1700 in plastic models) without flex, maintaining efficiency in high-pressure setups.
Q3: Is 85 dB(A) too loud for indoor use?
Suitable for industrial floors. For offices, pair with acoustic ducting or choose quieter models (e.g., FB3G220 at 71 dB(A)).
Q4: How does MODBUS enhance control?
Enables real-time RPM monitoring, fault alerts (e.g., overheating), and synchronized multi-fan operation via building management systems.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |