Availability: | |
---|---|
Quantity: | |
FB3G355-2APK-60
Fanova
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 3.3±10% |
转速 Speed(RPM) | min-1 | 2100±5% |
功率消耗 Power consumption | W | 750±10% |
声压级 Sound Pressure Level | dB(A) | 87±5% |
最大风量 Max. Air Flow | CFM / m3/H | 2942.5/5000 |
最大静压 Max. Static Pressure | In.wg /Pa | 4.0/1000 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP54 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FB3G355-2APK-60 is a corrosion-resistant centrifugal fan engineered for aggressive environments requiring high static pressure. Featuring a unique glass-fiber-reinforced plastic impeller and BLEC102 EC motor, it delivers 5,000 m³/h airflow at 1,000 Pa force. With IP54 protection, MODBUS compatibility, and 230V single-phase operation, it excels in chemical, marine, or high-humidity applications where metal components would degrade.
Chemical-Resistant Construction
Glass-fiber-reinforced polypropylene impeller withstands corrosive fumes, moisture, and salt spray—ideal for wastewater treatment, chemical processing, or coastal installations.
High-Pressure Performance
Generates exceptional 1,000 Pa static pressure at 2,100 RPM (±5%), enabling airflow through dense filters or long duct runs in compact systems.
Smart Industrial Control
Supports 0–10V/PWM speed modulation and RS485/MODBUS protocol. Includes +10VDC output for sensors and FG tachometer (5 pulses/rev) for system feedback.
Integrated Safety Monitoring
Alarm contacts (NC/COM) trigger during faults (overheat, lock-rotor). Protections include reverse polarity blocking and wide voltage tolerance (184–270V AC).
Chemical exhaust: Fume scrubbers, laboratory ventilation.
Marine/offshore: Engine room cooling, dehumidification systems.
Food processing: Corrosive vapor removal, washdown areas.
Industrial dehumidifiers: High-pressure drying systems.
Q: Plastic vs. aluminum impeller durability?
A: Superior corrosion resistance but lower max temperature (60°C vs. 80°C for aluminum). Avoid impacts exceeding 50J.
Q: Noise level at full load?
A: 87 dB(A) ±5%—recommend ducted installation or acoustic enclosures.
Q: Can MODBUS replace analog control?
A: Yes. Use RSA/RSB pins for digital speed commands—contact support for MODBUS registers.
Q: Weight specifications?
A: 3,600g (fan)/400g (inlet)—lighter than equivalent metal impellers.
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 3.3±10% |
转速 Speed(RPM) | min-1 | 2100±5% |
功率消耗 Power consumption | W | 750±10% |
声压级 Sound Pressure Level | dB(A) | 87±5% |
最大风量 Max. Air Flow | CFM / m3/H | 2942.5/5000 |
最大静压 Max. Static Pressure | In.wg /Pa | 4.0/1000 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP54 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FB3G355-2APK-60 is a corrosion-resistant centrifugal fan engineered for aggressive environments requiring high static pressure. Featuring a unique glass-fiber-reinforced plastic impeller and BLEC102 EC motor, it delivers 5,000 m³/h airflow at 1,000 Pa force. With IP54 protection, MODBUS compatibility, and 230V single-phase operation, it excels in chemical, marine, or high-humidity applications where metal components would degrade.
Chemical-Resistant Construction
Glass-fiber-reinforced polypropylene impeller withstands corrosive fumes, moisture, and salt spray—ideal for wastewater treatment, chemical processing, or coastal installations.
High-Pressure Performance
Generates exceptional 1,000 Pa static pressure at 2,100 RPM (±5%), enabling airflow through dense filters or long duct runs in compact systems.
Smart Industrial Control
Supports 0–10V/PWM speed modulation and RS485/MODBUS protocol. Includes +10VDC output for sensors and FG tachometer (5 pulses/rev) for system feedback.
Integrated Safety Monitoring
Alarm contacts (NC/COM) trigger during faults (overheat, lock-rotor). Protections include reverse polarity blocking and wide voltage tolerance (184–270V AC).
Chemical exhaust: Fume scrubbers, laboratory ventilation.
Marine/offshore: Engine room cooling, dehumidification systems.
Food processing: Corrosive vapor removal, washdown areas.
Industrial dehumidifiers: High-pressure drying systems.
Q: Plastic vs. aluminum impeller durability?
A: Superior corrosion resistance but lower max temperature (60°C vs. 80°C for aluminum). Avoid impacts exceeding 50J.
Q: Noise level at full load?
A: 87 dB(A) ±5%—recommend ducted installation or acoustic enclosures.
Q: Can MODBUS replace analog control?
A: Yes. Use RSA/RSB pins for digital speed commands—contact support for MODBUS registers.
Q: Weight specifications?
A: 3,600g (fan)/400g (inlet)—lighter than equivalent metal impellers.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |