Availability: | |
---|---|
Quantity: | |
FB3G190-2APS-90
Fanova
Phase | ~ | 1~ |
Nominal Voltage | VAC | 230 |
Nominal voltage range | VAC | 184~270 |
Frequency | Hz | 50/60 |
Current draw | A | 1.2±10% |
Speed(RPM) | min-1 | 4250±5% |
Power consumption | W | 170±10% |
Sound Pressure Level | dB(A) | 74±5% |
Max. Air Flow | CFM / m3/H | 461.97/785 |
Max. Static Pressure | In.wg /Pa | 3.56/890 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
230V AC Backward-Curve Centrifugal Fan (190mm impeller, 170W) delivers 890 Pa high static pressure at 785 m³/h airflow, optimized for systems requiring compact size and robust pressure performance. Featuring an ultra-high 4,250 RPM speed and wide voltage input (184–270V AC), it targets demanding cooling applications in confined industrial or commercial spaces.
Ultra-High RPM Efficiency: 7-blade fiber-reinforced composite impeller achieves 890 Pa static pressure – 32% higher than standard 190mm centrifugal fans.
Precision-Balanced Rotation: Reduces vibration transmission by >25% at 4,250 RPM, minimizing noise to 74 dB(A).
Wide Voltage Resilience: Stable operation across 184–270V AC fluctuations (±10% grid variance).
0–10V/PWM Dynamic Control: Adjusts speed from 30% to 100% for real-time thermal load matching.
FG Tachometer Output: 4 pulses/revolution enable real-time diagnostics.
Fiber-Reinforced Polymer Impeller: Withstands mechanical stress at high RPM while reducing weight (total fan: 1,550g).
IP44 Protection: Sealed against dust (≥1mm particles) and water splashes.
-25°C to 60°C Operating Range: Ball bearings ensure cold-start reliability.
Inrush Current Suppression: Soft-start circuit limits startup surge to <150% rated current.
Dual Thermal Cutoffs: Independent protection for motor windings and control electronics.
Automatic Voltage Shutdown: Triggers at <184V or >270V input.
Laser Cooling Systems: High-pressure airflow for CO₂ laser tubes and cutting heads.
3D Printing Enclosures: Heat dissipation in industrial additive manufacturing chambers.
Compact Air Purifiers: Overcoming HEPA filter resistance in mobile units.
Medical Sterilizers: Forced convection cooling for autoclaves and lab equipment.
Phase | ~ | 1~ |
Nominal Voltage | VAC | 230 |
Nominal voltage range | VAC | 184~270 |
Frequency | Hz | 50/60 |
Current draw | A | 1.2±10% |
Speed(RPM) | min-1 | 4250±5% |
Power consumption | W | 170±10% |
Sound Pressure Level | dB(A) | 74±5% |
Max. Air Flow | CFM / m3/H | 461.97/785 |
Max. Static Pressure | In.wg /Pa | 3.56/890 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
230V AC Backward-Curve Centrifugal Fan (190mm impeller, 170W) delivers 890 Pa high static pressure at 785 m³/h airflow, optimized for systems requiring compact size and robust pressure performance. Featuring an ultra-high 4,250 RPM speed and wide voltage input (184–270V AC), it targets demanding cooling applications in confined industrial or commercial spaces.
Ultra-High RPM Efficiency: 7-blade fiber-reinforced composite impeller achieves 890 Pa static pressure – 32% higher than standard 190mm centrifugal fans.
Precision-Balanced Rotation: Reduces vibration transmission by >25% at 4,250 RPM, minimizing noise to 74 dB(A).
Wide Voltage Resilience: Stable operation across 184–270V AC fluctuations (±10% grid variance).
0–10V/PWM Dynamic Control: Adjusts speed from 30% to 100% for real-time thermal load matching.
FG Tachometer Output: 4 pulses/revolution enable real-time diagnostics.
Fiber-Reinforced Polymer Impeller: Withstands mechanical stress at high RPM while reducing weight (total fan: 1,550g).
IP44 Protection: Sealed against dust (≥1mm particles) and water splashes.
-25°C to 60°C Operating Range: Ball bearings ensure cold-start reliability.
Inrush Current Suppression: Soft-start circuit limits startup surge to <150% rated current.
Dual Thermal Cutoffs: Independent protection for motor windings and control electronics.
Automatic Voltage Shutdown: Triggers at <184V or >270V input.
Laser Cooling Systems: High-pressure airflow for CO₂ laser tubes and cutting heads.
3D Printing Enclosures: Heat dissipation in industrial additive manufacturing chambers.
Compact Air Purifiers: Overcoming HEPA filter resistance in mobile units.
Medical Sterilizers: Forced convection cooling for autoclaves and lab equipment.
Voltage Output | Output +10VDC, max. 1.1 mA (Can be used as speed control input voltage or FG signal pull-up voltage,and need to be circumscribed in series with a pull -up resister, details as connection diagram.) | |
Dielectric Resistance | 10mA maximum at 1800VAC 50Hz one second Between frame and (+) terminal | |
Life Expectance | 50,000 Hours(L10) | |
Leakage Current | ≤3.5mA (Max. ) | |
Direction of Air Flow | Straight forward from air outlet | |
Motor | External rotor EC motor | |
Technical features | Motor current limitation | |
Soft starting Protection | ||
Under/Over voltage detection | ||
Thermal overload protection for electronics/motor | ||
Line undervoltage detection | ||
Locked-rotor Protection | ||
Reverse Polarity Protection | ||
Operating Temperature | -25ºC (Min. ) | 60ºC (Max. ) |
Heat sink of IC | 115ºC (Max. ) | |
Other electronic parts | 85ºC (Max. ) | |
Ball bering | 80ºC (Max. ) | |
Lead Wire | 120ºC (Max. ) | |
Storage Temperature | -40ºC to 75ºC | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH | |
Electronics housing material | Die-cast aluminum | |
Operation Mode | S1 | |
Motor bearing | Ball bearing | |
Valid For Approval/Standard | CE,RoHS,ErP2015 |
Voltage Output | Output +10VDC, max. 1.1 mA (Can be used as speed control input voltage or FG signal pull-up voltage,and need to be circumscribed in series with a pull -up resister, details as connection diagram.) | |
Dielectric Resistance | 10mA maximum at 1800VAC 50Hz one second Between frame and (+) terminal | |
Life Expectance | 50,000 Hours(L10) | |
Leakage Current | ≤3.5mA (Max. ) | |
Direction of Air Flow | Straight forward from air outlet | |
Motor | External rotor EC motor | |
Technical features | Motor current limitation | |
Soft starting Protection | ||
Under/Over voltage detection | ||
Thermal overload protection for electronics/motor | ||
Line undervoltage detection | ||
Locked-rotor Protection | ||
Reverse Polarity Protection | ||
Operating Temperature | -25ºC (Min. ) | 60ºC (Max. ) |
Heat sink of IC | 115ºC (Max. ) | |
Other electronic parts | 85ºC (Max. ) | |
Ball bering | 80ºC (Max. ) | |
Lead Wire | 120ºC (Max. ) | |
Storage Temperature | -40ºC to 75ºC | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH | |
Electronics housing material | Die-cast aluminum | |
Operation Mode | S1 | |
Motor bearing | Ball bearing | |
Valid For Approval/Standard | CE,RoHS,ErP2015 |