FG3G500-4APL-31带网罩
Fanova
相 Phase | ~ | 3~ |
额定电压 Nominal Voltage | VAC | 380 |
电压范围 Nominal voltage range | VAC | 304~456 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 1.5±10% |
转速 Speed(RPM) | min-1 | 1680±5% |
功率消耗 Power consumption | W | 850±10% |
声压级 Sound Pressure Level | dB(A) | 78.4±5% |
最大风量 Max. Air Flow | CFM / m3/H | 6120.4/10400 |
最大静压 Max. Static Pressure | In.wg /Pa | 1.2/300 |
绝缘等级 Insulation class | ~ | Class F |
防护等级 Degree of protection | ~ | IP54 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FG3G500-4APL-31 Guarded Axial Fan by Fanova (Suzhou) Motor Technology is a heavy-duty industrial solution combining high-volume airflow (10,400 m³/h) with integrated safety grilles. Powered by a 380V three-phase EC motor, it delivers robust 300 Pa static pressure while featuring fiberglass-reinforced blades for corrosive/dusty environments. With IP54 protection, MODBUS connectivity, and thermal safeguards, it excels in demanding ventilation scenarios. CE/RoHS/ErP2015 certified.
Guarded High-Capacity Airflow
Integrated safety grille enables 10,400 m³/h airflow—ideal for exposed installations—while preventing foreign object ingress in factories or warehouses.
Three-Phase Smart Control
380V EC motor supports 0–10VDC/PWM and RS485/MODBUS protocols via dedicated RSA/RSB wires for industrial automation integration.
Reinforced Industrial Build
Fiberglass-reinforced polypropylene impeller resists chemical corrosion. IP54 rating protects against dust/water in harsh environments (-25°C to 60°C).
Proactive Safety System
Alarm switches (NC/COM) trigger during faults (overheat/stall). Includes tachometer output (5 pulses/revolution) for real-time RPM monitoring.
Factory Floor Ventilation: High-volume air exchange in manufacturing plants.
Warehouse Safety Systems: Guarded exhaust for dust-prone storage areas.
Agricultural Air Handling: Corrosion-resistant airflow in fertilizer/feed processing.
HVAC Reinforcement: Supplemental airflow in large commercial duct systems.
Q: Does the grille impact airflow efficiency?
A: No. Aerodynamically optimized design maintains 10,400 m³/h flow with <3% reduction vs. unguarded models.
Q: Can MODBUS control override PWM signals?
A: Yes. RS485/MODBUS takes priority when both protocols are connected.
Q: How to clean the fiberglass impeller?
A: Use low-pressure air or soft brush. Avoid solvents that degrade polypropylene.
Q: What’s the purpose of the alarm switch (NC/COM)?
A: Closes during faults (e.g., motor lock). Connect to PLC/light for instant alerts.
相 Phase | ~ | 3~ |
额定电压 Nominal Voltage | VAC | 380 |
电压范围 Nominal voltage range | VAC | 304~456 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 1.5±10% |
转速 Speed(RPM) | min-1 | 1680±5% |
功率消耗 Power consumption | W | 850±10% |
声压级 Sound Pressure Level | dB(A) | 78.4±5% |
最大风量 Max. Air Flow | CFM / m3/H | 6120.4/10400 |
最大静压 Max. Static Pressure | In.wg /Pa | 1.2/300 |
绝缘等级 Insulation class | ~ | Class F |
防护等级 Degree of protection | ~ | IP54 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FG3G500-4APL-31 Guarded Axial Fan by Fanova (Suzhou) Motor Technology is a heavy-duty industrial solution combining high-volume airflow (10,400 m³/h) with integrated safety grilles. Powered by a 380V three-phase EC motor, it delivers robust 300 Pa static pressure while featuring fiberglass-reinforced blades for corrosive/dusty environments. With IP54 protection, MODBUS connectivity, and thermal safeguards, it excels in demanding ventilation scenarios. CE/RoHS/ErP2015 certified.
Guarded High-Capacity Airflow
Integrated safety grille enables 10,400 m³/h airflow—ideal for exposed installations—while preventing foreign object ingress in factories or warehouses.
Three-Phase Smart Control
380V EC motor supports 0–10VDC/PWM and RS485/MODBUS protocols via dedicated RSA/RSB wires for industrial automation integration.
Reinforced Industrial Build
Fiberglass-reinforced polypropylene impeller resists chemical corrosion. IP54 rating protects against dust/water in harsh environments (-25°C to 60°C).
Proactive Safety System
Alarm switches (NC/COM) trigger during faults (overheat/stall). Includes tachometer output (5 pulses/revolution) for real-time RPM monitoring.
Factory Floor Ventilation: High-volume air exchange in manufacturing plants.
Warehouse Safety Systems: Guarded exhaust for dust-prone storage areas.
Agricultural Air Handling: Corrosion-resistant airflow in fertilizer/feed processing.
HVAC Reinforcement: Supplemental airflow in large commercial duct systems.
Q: Does the grille impact airflow efficiency?
A: No. Aerodynamically optimized design maintains 10,400 m³/h flow with <3% reduction vs. unguarded models.
Q: Can MODBUS control override PWM signals?
A: Yes. RS485/MODBUS takes priority when both protocols are connected.
Q: How to clean the fiberglass impeller?
A: Use low-pressure air or soft brush. Avoid solvents that degrade polypropylene.
Q: What’s the purpose of the alarm switch (NC/COM)?
A: Closes during faults (e.g., motor lock). Connect to PLC/light for instant alerts.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |