Availability: | |
---|---|
Quantity: | |
FS3G200-48GL-90
Fanova
Nominal Voltage | VDC | 48 |
Nominal voltage range | VDC | 36~57 |
Current draw | A | 4.6±10% |
Speed(RPM) | min-1 | 1600±5% |
Power consumption | W | 200±10% |
Sound Pressure Level | dB(A) | 74±5% |
Max. Air Flow | CFM / m3/H | 588.5/1000 |
Max. Static Pressure | In.wg /Pa | 3.92/980 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
The FS3G200-48GL-90 is a single-inlet centrifugal DC fan engineered for demanding industrial ventilation and cooling applications. It delivers up to 1000 m³/h airflow and 980 Pa static pressure through a robust 200mm galvanized steel impeller driven by a brushless DC motor (BLDC102). Designed for continuous operation (S1 duty), it features IP44 protection and complies with CE, RoHS, and ErP standards, ensuring reliability in harsh environments.
Wide Voltage Resilience
Operates seamlessly from 36V to 57V DC, making it ideal for unstable power grids or battery-backed systems without additional stabilizers.
Smart Control Integration
Supports dual 0-10V/PWM speed control and outputs real-time FG tach signals (3 pulses/revolution) for precise system monitoring and automation.
Industrial-Grade Protections
Embedded safeguards include soft-start, locked-rotor detection, reverse-polarity cutoff, and thermal overload protection for electronics/motor, minimizing downtime.
High-Efficiency Airflow Design
Combines a 38-blade galvanized impeller with an external-rotor BLDC motor to maximize static pressure (980 Pa) while reducing acoustic noise to 74 dB(A).
Industrial Machinery Cooling: HVAC systems, laser cutters, and CNC equipment requiring high static pressure.
Power Electronics Ventilation: Servers, UPS, and inverters in environments up to 60°C.
Dynamic Airflow Control: Applications needing PWM-based speed adjustments (e.g., cleanrooms, agricultural vents).
Q1: Can the fan run without an impeller or load?
A: No. The motor must operate with the impeller attached. Unloaded use may damage bearings or electronics.
Q2: How to avoid wiring errors?
A: Connect red wire to +48VDC, yellow to PWM/0-10V control, and blue to ground. Reversing power/control lines risks burnout.
Q3: Why avoid touching the impeller during startup?
A: Soft-start technology may delay rotation. Contact during this phase can cause injury if the fan suddenly engages.
Nominal Voltage | VDC | 48 |
Nominal voltage range | VDC | 36~57 |
Current draw | A | 4.6±10% |
Speed(RPM) | min-1 | 1600±5% |
Power consumption | W | 200±10% |
Sound Pressure Level | dB(A) | 74±5% |
Max. Air Flow | CFM / m3/H | 588.5/1000 |
Max. Static Pressure | In.wg /Pa | 3.92/980 |
Insulation class | ~ | Class B |
Degree of protection | ~ | IP44 |
Control Input | ~ | 0~10VDC / PWM |
Signal Output | ~ | FG (Tach output ) |
The FS3G200-48GL-90 is a single-inlet centrifugal DC fan engineered for demanding industrial ventilation and cooling applications. It delivers up to 1000 m³/h airflow and 980 Pa static pressure through a robust 200mm galvanized steel impeller driven by a brushless DC motor (BLDC102). Designed for continuous operation (S1 duty), it features IP44 protection and complies with CE, RoHS, and ErP standards, ensuring reliability in harsh environments.
Wide Voltage Resilience
Operates seamlessly from 36V to 57V DC, making it ideal for unstable power grids or battery-backed systems without additional stabilizers.
Smart Control Integration
Supports dual 0-10V/PWM speed control and outputs real-time FG tach signals (3 pulses/revolution) for precise system monitoring and automation.
Industrial-Grade Protections
Embedded safeguards include soft-start, locked-rotor detection, reverse-polarity cutoff, and thermal overload protection for electronics/motor, minimizing downtime.
High-Efficiency Airflow Design
Combines a 38-blade galvanized impeller with an external-rotor BLDC motor to maximize static pressure (980 Pa) while reducing acoustic noise to 74 dB(A).
Industrial Machinery Cooling: HVAC systems, laser cutters, and CNC equipment requiring high static pressure.
Power Electronics Ventilation: Servers, UPS, and inverters in environments up to 60°C.
Dynamic Airflow Control: Applications needing PWM-based speed adjustments (e.g., cleanrooms, agricultural vents).
Q1: Can the fan run without an impeller or load?
A: No. The motor must operate with the impeller attached. Unloaded use may damage bearings or electronics.
Q2: How to avoid wiring errors?
A: Connect red wire to +48VDC, yellow to PWM/0-10V control, and blue to ground. Reversing power/control lines risks burnout.
Q3: Why avoid touching the impeller during startup?
A: Soft-start technology may delay rotation. Contact during this phase can cause injury if the fan suddenly engages.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |