Availability: | |
---|---|
Quantity: | |
FG3G450-2APN-20不带网罩
Fanova
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 1.9±10% |
转速 Speed(RPM) | min-1 | 1600±5% |
功率消耗 Power consumption | W | 420±10% |
声压级 Sound Pressure Level | dB(A) | 68±5% |
最大风量 Max. Air Flow | CFM / m3/H | 3619.275/6150 |
最大静压 Max. Static Pressure | In.wg /Pa | 1.0/250 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP54 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FG3G450-2APN-20 is a high-volume EC axial fan engineered for large-scale industrial ventilation. Featuring a corrosion-resistant 450mm plastic-glass fiber impeller and powered by a single-phase EC motor (BLEC102), it delivers massive airflow (6150 m³/H) at low noise (68 dB(A)). Designed for 230VAC systems (184–270VAC range) with IP54 protection and Modbus-enabled control.
Corrosion-Resistant Airflow
5-blade plastic-glass fiber impeller withstands humid/chemical environments while moving high air volumes at 1600 RPM.
Industrial Control Integration
Supports 0–10VDC/PWM or RS485 Modbus (RSA/RSB) for automated speed adjustment, with +10VDC output for signal conditioning.
Counter-Rotation Design
Unique anticlockwise rotation (viewed toward rotor) optimizes airflow direction for specific duct/vent configurations.
HVAC Systems: High-volume air exchange in factories, warehouses, and commercial buildings.
Agricultural Ventilation: Livestock barns, greenhouse climate control.
Waste Management: Exhaust systems for composting/recycling facilities.
Energy Infrastructure: Cooling for transformer stations or turbine halls.
Q: Why choose plastic-glass fiber blades over metal?
A: Superior corrosion resistance in humid/chemical environments, with reduced weight for easier installation.
Q: Can rotation direction be reversed?
A: No—factory-set anticlockwise; consult technical support for custom motor configurations.
Q: Is the Modbus interface isolated?
A: Yes—RS485 (RSA/RSB) includes noise immunity for industrial environments.
Q: Why "without protective guard"?
A: For custom installations where external guards are provided; add safety mesh if exposed to contact.
相 Phase | ~ | 1~ |
额定电压 Nominal Voltage | VAC | 230 |
电压范围 Nominal voltage range | VAC | 184~270 |
频率 Frequency | Hz | 50/60 |
电流消耗 Current draw | A | 1.9±10% |
转速 Speed(RPM) | min-1 | 1600±5% |
功率消耗 Power consumption | W | 420±10% |
声压级 Sound Pressure Level | dB(A) | 68±5% |
最大风量 Max. Air Flow | CFM / m3/H | 3619.275/6150 |
最大静压 Max. Static Pressure | In.wg /Pa | 1.0/250 |
绝缘等级 Insulation class | ~ | Class B |
防护等级 Degree of protection | ~ | IP54 |
控制方式 Control Input | ~ | 0~10VDC / PWM |
信号输出 Signal Output | ~ | FG (Tach output ) |
The FG3G450-2APN-20 is a high-volume EC axial fan engineered for large-scale industrial ventilation. Featuring a corrosion-resistant 450mm plastic-glass fiber impeller and powered by a single-phase EC motor (BLEC102), it delivers massive airflow (6150 m³/H) at low noise (68 dB(A)). Designed for 230VAC systems (184–270VAC range) with IP54 protection and Modbus-enabled control.
Corrosion-Resistant Airflow
5-blade plastic-glass fiber impeller withstands humid/chemical environments while moving high air volumes at 1600 RPM.
Industrial Control Integration
Supports 0–10VDC/PWM or RS485 Modbus (RSA/RSB) for automated speed adjustment, with +10VDC output for signal conditioning.
Counter-Rotation Design
Unique anticlockwise rotation (viewed toward rotor) optimizes airflow direction for specific duct/vent configurations.
HVAC Systems: High-volume air exchange in factories, warehouses, and commercial buildings.
Agricultural Ventilation: Livestock barns, greenhouse climate control.
Waste Management: Exhaust systems for composting/recycling facilities.
Energy Infrastructure: Cooling for transformer stations or turbine halls.
Q: Why choose plastic-glass fiber blades over metal?
A: Superior corrosion resistance in humid/chemical environments, with reduced weight for easier installation.
Q: Can rotation direction be reversed?
A: No—factory-set anticlockwise; consult technical support for custom motor configurations.
Q: Is the Modbus interface isolated?
A: Yes—RS485 (RSA/RSB) includes noise immunity for industrial environments.
Q: Why "without protective guard"?
A: For custom installations where external guards are provided; add safety mesh if exposed to contact.
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |
Storage Humidity | 5% to 95% RH |
Life Expectance | 50,000 Hours(L10),At 40℃ room, humidity 15%~65%RH |
Technical features | Motor current limitation |
Soft starting Protection | |
Under/Over voltage detection | |
Thermal overload protection for electronics/motor | |
Line undervoltage detection | |
Locked-rotor Protection | |
Reverse Polarity Protection |
Operating Temperature | Fan | -25℃ (Min. )~60℃ (Max. ) |
Heat sink of IC | 115℃ (Max. ) | |
Other electronic parts | 85℃ (Max. ) | |
Ball bearing | 80℃ (Max. ) | |
Lead Wire | 120℃ (Max. ) | |
Storage Temperature | -40℃ to 75℃ | |
Operating Humidity | 5% to 90% RH | |